Calibration for kbd300A




Download 7.97 Kb.
NameCalibration for kbd300A
A typeDocumentation
Calibration for KBD300A


  1. Plug the unit in. Watch the LED display and a number will flash 5 times this is the version of the controller firmware. The numbers will range between 40 and 60. If the number is below 51 the unit does not need calibration. If it is 51 or above the following calibration is needed.

  2. PAN calibration.

Unplug the cable from the back of the KBD300 and then press and hold the

F1 key continue holding this key down while you plug the cable back into

the unit DO NOT let go until the LED display has a number holding steady

this should range from 0 to 15, if this number is a lot higher than 15 the

joystick is bad. If the shift light is on this is a negative number if it is off it

is a positive number. The joystick has a 33 point span. Now push the

joystick all the way to the right and then all the way back to the left and then

let go and let it snap back to center. Now push AUX ON and hold for 1

second then let go.

  1. TILT calibration.

Unplug the cable from the back of the KBD300 and then press and hold the

F2 key continue holding this key down while you plug the cable back into

the unit DO NOT let go until the LED display has a number holding steady

this should range from 0 to 15, if this number is a lot higher than 15 the

joystick is bad. Now push the joystick all the way up and then all the way

back down and then let go and let it snap back to center.

Now push AUX ON and hold for 1second then let go.

  1. ZOOM calibration.

Unplug the cable from the back of the KBD300 and then press and hold the

F3 key continue holding this key down while you plug the cable back into

the unit DO NOT let go until the LED display has a number holding steady

this should range from 0 to 15, if this number is a lot higher than 15 the

joystick is bad. Now twist the joystick all the way to the right and let go,

then twist all the way to the left and let go.

Now push AUX ON and hold for 1second then let go.

  1. The calibration is now done so unplug and replug the cable once more and

you should have control of the domes.

Share in:

Related:

Calibration for kbd300A iconZeltex Calibration Software

Calibration for kbd300A iconOperational and calibration faqs

Calibration for kbd300A iconCalibration Jar Set-up

Calibration for kbd300A iconZx-440 Calibration Software

Calibration for kbd300A iconStandard Calibration Procedure

Calibration for kbd300A iconPolar Calibration and Alignment heq5 pro

Calibration for kbd300A iconAbstract Pollution transport models are based on field data and the...

Calibration for kbd300A iconSceneLink is the program that allows Display pc access to the Scene...

Calibration for kbd300A iconHave Varied Experience of in Project/ Routine Maintenance, Installation,...

Calibration for kbd300A iconSeeking a challenging position as Biomedical Engineer in a major...

Calibration for kbd300A iconQuick guide for processing/adjusting static/fast static gps data...

Calibration for kbd300A iconReport Calibration & qa report




manual




When copying material provide a link © 2017
contacts
manual-guide.com
search