This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section


Download 172.61 Kb.
NameThis Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section
page1/3
A typeDocumentation
manual-guide.com > manual > Documentation
  1   2   3

Copyright 2011 AIA MasterSpec Full Length 11/11

PRODUCT MASTERSPEC LICENSED BY ARCOM TO PELLA CORPORATION.


Copyright 2011 by The American Institute of Architects (AIA)

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

This Product MasterSpec Section is licensed by ARCOM to Pella Corporation ("Licensee").

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section.

Revisions made to the original MasterSpec text are made solely by the Licensee and are not endorsed by, or representative of the opinions of, ARCOM or The American Institute of Architects (AIA). Neither AIA nor ARCOM are liable in any way for such revisions or for the use of this Product MasterSpec Section by any end user. A qualified design professional should review and edit the document to suit project requirements.

For more information, contact Pella Corporation, 102 Main Street, Pella, IA 50219; phone: (800) 847-3552 or (641) 621-1000; fax: (641) 621-6487; Website: www.pellacommercial.com; e-mail: commercial@pella.com.

For information about MasterSpec contact ARCOM at (800) 424-5080 or visit www.MasterSpec.com.

SECTION 085200 - WOOD WINDOWS

Revise this Section by deleting and inserting text to meet Project-specific requirements.

This Section uses the term "Architect." Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions.

  1. GENERAL

        1. RELATED DOCUMENTS

Retain or delete this article in all Sections of Project Manual.

          1. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

        1. SUMMARY

Retain applicable option in paragraph below for clad wood windows, or delete both options if windows are not clad.

          1. Section includes aluminum-clad wood windows.

        1. PREINSTALLATION MEETINGS

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

          1. Preinstallation Conference: Conduct conference at [Project site] <Insert location>.

Retain subparagraphs below if required. If retaining, revise to include product-specific requirements.

            1. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.

            2. Review, discuss, and coordinate the interrelationship of wood windows with other exterior wall components. Include provisions for anchoring, flashing, weeping, sealing perimeters, and protecting finishes.

            3. Review and discuss the sequence of work required to construct a watertight and weathertight exterior building envelope.

            4. Inspect and discuss the condition of substrate and other preparatory work performed by other trades.

If needed, insert list of conference participants not mentioned in Section 013100 "Project Management and Coordination."

        1. ACTION SUBMITTALS

          1. Product Data: For each type of product.

            1. Include construction details, material descriptions, glazing and fabrication methods, dimensions of individual components and profiles, hardware, and finishes for wood windows.

          2. LEED Submittals:

First option in "Certificates for (Credit MR 6) (Credit MR 7)" Subparagraph below applies to LEED-CS; second applies to LEED-NC, LEED-CI, and LEED for Schools.

            1. Certificates for [Credit MR 6] [Credit MR 7]: Chain-of-custody certificates indicating that windows comply with forest certification and chain-of-custody requirements. Include statement indicating cost for each certified wood product.

          1. Shop Drawings: Include plans, elevations, sections, hardware, accessories, insect screens, operational clearances, and details of installation, including anchor, flashing, and sealant installation.

Retain "Samples" Paragraph below for single-stage Samples, with a subordinate list if applicable. Retain "Samples for Initial Selection" and "Samples for Verification" paragraphs for two-stage Samples.

          1. Samples: For each exposed product and for each color specified, [2 by 4 inches (50 by 100 mm)] <Insert dimensions> in size.

          2. Samples for Initial Selection: For units with factory-applied color finishes.

            1. Include similar Samples of hardware and accessories involving color selection.

          3. Samples for Verification: For wood windows and components required, prepared on Samples of size indicated below:

            1. Exposed Finishes: [2 by 4 inches (50 by 100 mm)] <Insert dimensions>.

            2. Exposed Hardware: Full-size units.

          4. Product Schedule: For wood windows. Use same designations indicated on Drawings.

        1. INFORMATIONAL SUBMITTALS

Coordinate "Qualification Data" Paragraph below with qualification requirements in Section 014000 "Quality Requirements" and as may be supplemented in "Quality Assurance" Article.

          1. Qualification Data: For manufacturer and Installer.

          2. Product Test Reports: For each type of wood window, for tests performed by a qualified testing agency.

Retain "Field quality-control reports" Paragraph below if Contractor is responsible for field quality-control testing and inspecting.

          1. Field quality-control reports.

          2. Sample Warranties: For manufacturer's warranties.

        1. QUALITY ASSURANCE

Retain option in "Manufacturer Qualifications" Paragraph below if required for LEED-CS Credit MR 6, LEED-NC Credit MR 7, LEED-CI Credit MR 7, or LEED for Schools Credit MR 7. Before retaining, verify that manufacturers comply.

          1. Manufacturer Qualifications: A manufacturer capable of fabricating wood windows that meet or exceed performance requirements indicated and of documenting this performance by test reports, and calculations[ and who is certified for chain of custody by an FSC-accredited certification body].

If retaining option in "Manufacturer Qualifications" Paragraph above, also retain "Vendor Qualifications" Paragraph below.

          1. Vendor Qualifications: A vendor that is certified for chain of custody by an FSC-accredited certification body.

          2. Installer Qualifications: An installer acceptable to wood window manufacturer or supplier for installation of units required for this Project.

Coordinate "Mockups" Paragraph below with air barrier Sections for building and preconstruction testing of integrated wall mockups that include windows; insert additional requirements if applicable.

          1. Mockups: Build mockups to verify selections made under Sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution.

Indicate portion of wall represented by mockup on Drawings or draw mockup as separate element.

            1. Build mockup of typical wall area as shown on Drawings.

            2. Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless Architect specifically approves such deviations in writing.

Insert "Field Conditions" Article and requirements for field measurements for existing construction that requires custom-fabricated window replacements.

        1. WARRANTY

When warranties are required, verify with Owner's counsel that warranties stated in this article are not less than remedies available to Owner under prevailing local laws.

          1. Manufacturer's Warranty: Manufacturer agrees to repair or replace wood windows that fail in materials or workmanship within specified warranty period.

            1. Failures include, but are not limited to, the following:

              1. Failure to meet performance requirements.

              2. Structural failures including excessive deflection, water leakage, and air infiltration.

              3. Faulty operation of movable sash and hardware.

              4. Deterioration of materials and finishes beyond normal weathering.

              5. Failure of insulating glass.

Verify available warranties and warranty periods for units and components. Some manufacturers might insist that warranty periods begin on date of manufacture or sale.

            1. Warranty Period:

              1. Window: 10 years from date of Substantial Completion.

Warranty period for glazing units varies by type.

              1. Glazing Units, Non-laminated: 20 years from date of Substantial Completion.

              2. Glazing Units, Laminated: 10 years from date of Substantial Completion.

Warranty period for aluminum finish depends on type. Baked-on enamel finishes often have 10-year warranties; high-performance fluoropolymer finishes often have 20-year warranties. Revise "Aluminum-Cladding Finish" Subparagraph below if finish warranties are available.

              1. Aluminum-Cladding Finish: [10] [20] years from date of Substantial Completion.

  1. PRODUCTS

See Editing Instruction No. 1 in the Evaluations in Section 085000 "Windows" for cautions about named manufacturers and products. For an explanation of options and Contractor's product selection procedures, see Section 016000 "Product Requirements."

        1. MANUFACTURERS

Retain "Basis-of-Design Product" Paragraph and list of manufacturers below to identify a specific product or a comparable product from manufacturers listed. Retain option and delete insert note if manufacturer's name and model number are indicated on Drawings.

          1. Basis-of-Design Product: Subject to compliance with requirements, provide Pella Corporation [Architect Series®] [Designer Series®] [Pella® ProLine] or comparable product by one of the following:

Retain manufacturers in lists below after verifying availability and suitability of products for applications indicated. Insert other manufacturers if required.

            1. Aluminum-Clad Wood Windows:

              1. EAGLE Window & Door, Inc.; an Andersen Window & Door company.

              2. Marvin Windows and Doors.

              3. <Insert manufacturer's name>.

            2. Wood Windows:

              1. Kolbe & Kolbe Millwork Co., Inc.

              2. Marvin Windows and Doors.

              3. <Insert manufacturer's name>.

          1. Source Limitations: Obtain wood windows from single source from single manufacturer.

        1. WINDOW PERFORMANCE REQUIREMENTS

See the Evaluations in Section 085000 "Windows" for discussions of performance requirements. Coordinate performance requirements with types of window operation (e.g., casement or double hung), glass type, and other variables. If performance requirements vary among types of windows, insert language to differentiate requirements among window types or show requirements in a schedule on Drawings.

          1. Product Standard: Comply with AAMA/WDMA/CSA 101/I.S.2/A440 for definitions and minimum standards of performance, materials, components, accessories, and fabrication unless more stringent requirements are indicated.

Retain requirements for WDMA certification and labeling if needed. Not all manufacturers that test products according to AAMA/WDMA/CSA 101/I.S.2/A440 requirements participate in WDMA's third-party certification program for listing and labeling wood windows.

            1. Window Certification: WDMA Hallmark certified with label attached to each window.

          1. Performance Class and Grade: AAMA/WDMA/CSA 101/I.S.2/A440 as follows:

            1. Minimum Performance Class: [R] [LC] [CW] [As indicated on Drawings] <Insert class>.

AAMA/WDMA/CSA 101/I.S.2/A440 establishes a gateway Performance Grade for windows to qualify for each Performance Class. The gateway Performance Grade is 15 for Class R, 25 for Class LC, and 30 for Class CW. For a particular project, the minimum Performance Grade for windows is typically based on the design pressure.

            1. Minimum Performance Grade: [15] [20] [25] [30] [35] [40] [45] [50] [As indicated on Drawings] <Insert grade>.

Retain "Thermal Transmittance" Paragraph below if required to comply with requirements of authorities having jurisdiction. Options below are based on Energy Star requirements effective January 2010. First option is for Northern Climate Zone, second is for North-Central Climate Zone, third is for South-Central Climate Zone, and fourth is for Southern Climate Zone.

          1. Thermal Transmittance: NFRC 100 maximum whole-window U-factor of [0.30 Btu/sq. ft. x h x deg F (1.71 W/sq. m x K)] [0.32 Btu/sq. ft. x h x deg F (1.83 W/sq. m x K)] [0.35 Btu/sq. ft. x h x deg F (2.0 W/sq. m x K)] [0.60 Btu/sq. ft. x h x deg F (3.43 W/sq. m x K)] <Insert value>.

Options in "Solar Heat-Gain Coefficient (SHGC)" Paragraph below are based on Energy Star requirements effective January 2010. First option is for North-Central Climate Zone, second is for South-Central climate zone, and third is for Southern Climate zone.

          1. Solar Heat-Gain Coefficient (SHGC): NFRC 200 maximum whole-window SHGC of [0.40] [0.30] [0.27] <Insert value>.

Retain "Outside-Inside Transmission Class (OITC)" or "Sound Transmission Class (STC)" paragraphs below after verifying availability of test data. STC evaluates construction subject to interior sound frequencies, while OITC evaluates an expanded sound-frequency range more representative of conditions to which the building envelope is subject, such as road, rail, and airplane traffic noise. OITC is generally the preferred evaluation method for exterior windows.

          1. Outside-Inside Transmission Class (OITC): Rated for not less than [
  1   2   3

Share in:

Related:

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...

This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section iconThis Product MasterSpec Section modifies the original MasterSpec...




manual


When copying material provide a link © 2017
contacts
manual-guide.com
search