415V  MCB

Auxiliary interlock of MCB OCB-1 sometimes not making contact.

New Auxiliary interlock fitted in OCB MCB.

199

4901

31323

ECR

GMO

3-Phase

WAG9

07-Jan-12

CLW

03-Sep-12

Oil cooler blower unit

01 No. foundation bolt open causes impeller blade broken.

OCB-2 changed.

240

4902

31332

ECR

GMO

3-Phase

WAG9

18-Feb-12

CLW

03-Sep-12

Oil cooler blower unit

Bonded. (C )

Bonded. (C )

198

4903

22899

CR

BSL

Conventional

WAP4

01-Dec-11

CLW

03-Sep-12

Traction Motor

Carbon brush for Hitachi TM 1) rubber cap worned out 2) all carbon brushes pigtail overheated & insulating sleeve damaged.

REPORTED TO CLW & FIRM VIDE L.NO. BSL/TRS/S/WTY/CARBON BRUSH-HITACHI/ACPL DT.22/09/12

277

4904

31352

SECR

BIA

3-Phase

WAG9

01-Aug-12

CLW

03-Sep-12

HT/LT cable

Loco tripping with fault NSC2: 0082 PS fault storage GBC. NSC side gate unit and GTO TM cables in junction box insulation tested found failing in 1 kv megger.

Cables and insulation sleeves changed.

33

4905

31352

SECR

BIA

3-Phase

WAG9

14-Aug-12

CLW

03-Sep-12

HT/LT cable

loco tripping with fault NSC2: 0082 PS fault storage GBC. TM-5 junction box flashed condition and insulation burnt. Protection sleeve provided over TM cables in junction box insulation tested found failing in 1 kv megger. Loco failed due to bad insulating material used over TM cables as protection sleeves.

Same changed.

20

4906

24605

SR

ED

Conventional

WAG7

10-Jul-12

BHEL

01-Sep-12

ESMON

SPM not working.

Defective PG changed.

53

4907

24594

SR

ED

Conventional

WAG7

14-Jun-12

BHEL

01-Sep-12

Compressor/Exhauster

Compressor-3 unusual sound.

CP-3 changed.

79

4908

24605

SR

ED

Conventional

WAG7

10-Jul-12

BHEL

31-Aug-12

ESMON

PG defective.

PG replaced.

52

4909

24616

SR

ED

Conventional

WAG7

12-Aug-12

BHEL

31-Aug-12

MPFDCS

In FDCS fault data "VE-DN coil or output wire shorted with BN. DJ tripped via VE-DN main output channel failed" fault logged.

Loco checked and no trouble noticed suspected output-2 card malfunctioning.

19

4910

24620

NR

LDH

Conventional

WAG7

21-Aug-12

BHEL

31-Aug-12

Control Circuit

Wire no. ZZ-966 & G993 in SB3BD flashed form thimble due to less gap in both thimbles

Both thimbles changed after creating a gap in both thimbles

10

4911

24620

NR

LDH

Conventional

WAG7

21-Aug-12

BHEL

31-Aug-12

Control Circuit

Wire no. ZZ-966 & G993 in SB3BD flashed form thimble due to less gap in both thimbles

Both thimbles changed after creating a gap in both thimbles

10

4912

22865

SER

SRC

Conventional

WAP4

26-Feb-11

CLW

30-Aug-12

MPFDCS

QSIT tripping. MPCS trouble. Attended by firm (M/s Stesalit) but given no satisfactory result.

Defective MPCS removed and M/s Medha make MPCS fitted.

551

4913

30311

ER

HWH

3-Phase

WAP7

15-Mar-12

CLW

30-Aug-12

Pn. Valve

Bogie -1 brake cylinder pressure 04 kg/cm2 and brake applied.

C3W distributer valve was defective, same changed.

168

4914

24600

NR

LDH

Conventional

WAG7

29-Mar-12

BHEL

30-Aug-12

SIV

SIV internal fault

GDU card of V phase defective, same replaced

154

4915

24601

SR

ED

Conventional

WAG7

14-Jun-12

BHEL

30-Aug-12

Miscellaneous

Cab AC not working & Heater not working but only blower working in both cabs.

In cab-1 control unit cable coupler connecting to roof AC was slack. Wire 1F and 1D in the control unit was inter changed and hence heater not working. In cab-2 compressor contactor coil connection was slack. Attended by M/s Lloyd on 22.1.2013.

77

4916

24576

NR

LDH

Conventional

WAG7

21-Dec-11

BHEL

29-Aug-12

SMGR

GR trouble.SMGR progression relay found, contacts flashed defective

Relay changed. ( M/s AAL)

252

4917

28485

SER

TATA

Conventional

WAG7

11-Aug-12

CLW

28-Aug-12

Transformer

TFP oil below min. mark

Loco checked at BNDM and found TFP oil leakage from TFP sample cock as its gasket was damaged condition.

17

4918

28485

SER

TATA

Conventional

WAG7

11-Aug-12

CLW

28-Aug-12

Miscellaneous

Cab-1 H/ not glowing in bright condition

Regarding H/L not glowing in dimmer condition checked and found back side of BD "K" coupler pin loose condition.

17

4919

24616

SR

ED

Conventional

WAG7

12-Aug-12

BHEL

28-Aug-12

Traction Motor

Noted heavy grooving mark over commutator of TM-1 & TM-3

TM-1 & 3 replaced.

16

4920

24592

NR

LDH

Conventional

WAG7

23-Apr-12

BHEL

27-Aug-12

CBC/Draft gear/TSC

Yoke pin of cab2 was found shifted upward 45 mm and retaining plate bent.

Extra liner was provided on the retaining paltes in both cabs.

126

4921

28494

ECR

MGS

Conventional

WAG7

18-Sep-13

CLW

27-Aug-12

Miscellaneous

Notch progress automatically.

Loco checked by firm staff Steslit and found MPCS out put card no1 defective.Same changed.

-387

4922

28484

SER

TATA

Conventional

WAG7

05-Aug-12

CLW

26-Aug-12

MPFDCS

DJ closing & opening by closing opening by HBA

Input card changed and function checked several times, found functioning satisfactorily.

21

4923

22839

SER SRC ConventionalWAP4 11-Aug-10CLW25-Aug-12RSI block"QLM, QOP-1 and QRSI dropped. RSI-1 6 nos. fuse open circuited and 6 no. diode punctured. RSI Make- Stesalit" Both RSIs changed at ELS/TATA. 745 4924 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW25-Aug-12HL/FL24V. Supply not coming on output. DC-DC converter changed. 211 4925 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW25-Aug-12Sensor (FDU, Speed, Pressure, Temp. OHE/ Voltage)FDU failed, Power supply defective. FDU changed. 211 4926 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW25-Aug-12Sensor (FDU, Speed, Pressure, Temp. OHE/ Voltage)FDU failed, Power supply defective. FDU changed. 211 4927 22893 SER SRC ConventionalWAP4 17-Sep-11CLW24-Aug-12SIVSTC Cell voltage very low. Firm representative attended the same and found Battery charger output voltage was 110V. Battery charger output voltage set at 110.5V with out load. Finally found ok. 342 4928 31350 SECR BIA 3-PhaseWAG9 30-Jul-12CLW24-Aug-12Vacuum Circuit Breaker (VCB)Loco received on date 26-08-12 with VCB cock isolated. RS pressure built up and VCB cock made normal found heavy air leakage from VCB. VCB cover opened and found air leakage from EP valve exhaust port continuously, causing VCB pressure not maintaining and getting VCB low pressure. VCB Replaced. After changing VCB, working checked found normal. 25 4929 28445 SCR KZJ ConventionalWAG7 08-May-12CLW24-Aug-12Auxiliary MotorLoco pilot after passing JM informed that experienced abnormal sound from HT compartment and DJ tripped with MPFDS message "DJ tripped Via MVSL-1". checked and found MVSL-1 blades broken and MVSL-1 not working. Section cleared by keeping HVSL-1 on "3" position. checked found MVSL-1 Cooling Fan Blades Broken. Bearing was found slack on shaft which lead to bearing un even revolution & resulting in breakage of fan blades.firm advised of this failure & replaced MVSL108 4930 31350 SECR BIA 3-PhaseWAG9 04-Aug-12CLW24-Aug-12Vacuum Circuit Breaker (VCB) Heavy air leakage from VCB. VCB cover opened and found air leakage from EP valve exhaust port continuously. Causing VCB pressure not maintaining and getting VCB low pressure. VCB changed.20 4931 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12EM ContactorAll EMC fix and mobile contact alignment not proper and contact gap is more (11mm) Same attended-7 4932 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12HT/LT cableAll power cables rubbing with channel due to gasket not provided.Same attended-7 4933 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12HT/LT cableSome cables hanging in BD board due to cable dressing not done. Same attended-7 4934 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12MiscellaneousBD 1, 2, 3 all bolts are slight loose. Same attended-7 4935 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12MiscellaneousTop of BD board only top gasket provided to avoid cable pressing but bottom side gasket not provided.Same attended-7 4936 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12HT/LT cableBoth cab all SB cables loose condition.Same attended-7 4937 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12SMGRSMGR BBC contact (Aux. contact) fixation bolt was loose. SMGR control block non modified.Same attended-7 4938 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12MiscellaneousBoth side AC control unit having 3 Nos. foundation bolt and one side fixation hole not matching.Same attended-7 4939 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12HT/LT cableAC control unit cable dressing not proper.Same attended-7 4940 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12Pn. ValveSMGR reducing valve - 3.8 kg/sq.cm and dropping - 0.8Kg/sq.cm.Same attended-7 4941 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12Traction MotorTM-3 MP 1&2 cable cross connected above cleat.Same attended-7 4942 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12Pn. ValveBPC2 relay found air leakage.Same attended-7 4943 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12MiscellaneousRGCP setting found 8.8 - 9.6 Kg/sq.cmSame attended-7 4944 22934 SER TATA ConventionalWAP4 30-Aug-12CLW23-Aug-12HT/LT cableCab-2 LP side horn pipe connecting pressure switch (for VCD) one incoming cable no. 701/2 pressed condition at bottom side of pneumatic channel caused insulation damaged and touching with channel. Same attended.-7 4945 30050 WR BRC 3-PhaseWAP5 28-Mar-12CLW23-Aug-12Pn. ValveMessage "brake system low pr. main reservoir" MCE off/on but no success. R/engine given. During joint checking at BL shed, CP2 metallic NRV (FTIL make) found defective causing air leakage through unloader valve. Metallic NR Valve replaced with spare one. Metallic NR Valve replaced with spare one. As a precautionary measure,cleaning of NRV started during every sch. inps instead of during IC only and blowing of BP/FP pn.pipe lines started. 148 4946 31331 ECR GMO 3-PhaseWAG9 29-Jun-12CLW21-Aug-12MiscellaneousCab-1 driver side & Cab-2 Asst. driver side wiper blade defective. Replaced by same blade from section. 53 4947 31331 ECR GMO 3-PhaseWAG9 29-Jun-12CLW21-Aug-12MiscellaneousCab-1 BC gauge defective as needle sticking. Same gauge changed from section. 53 4948 28458 SER TATA ConventionalWAG7 08-Jun-12CLW19-Aug-12EP ContactorHMCS-2 on IIIL-5 bottom contact deficient, contact not found in loco, one number screw fallen and found in flashed condition. Line contactor -5 changed. 72 4949 31315 ECR GMO 3-PhaseWAG9 10-May-12CLW18-Aug-12TransformerOil leakage from TFP-2 gate valve spandle 'O' ring. Gate valve changed. 100 4950 22840 SER SRC ConventionalWAP4 19-Aug-10CLW17-Aug-12RSI block"RSI-2 overheated. HRC fuse no.3 open circuited and diode no. 3 punctured. RSI Make- Stesalit" Both RSIs changed. 729 4951 28479 NCR CNB ConventionalWAG7 05-Aug-12CLW16-Aug-12TransformerQLM drop with TF oil splashed through conservator. TF oil DGA found C2H2 =6231.35ppm, C2H4=4119.44ppm, CH4=1460ppm, C2H6=256.91ppm, CO2=1093.07ppm, CO=1429.15ppm & H2=2668.38ppm. Oil BDV=31.1KV. TFP Make-BHEL, BHEL Sl. No. 2033892.TFP changed. TFP repaired & received under warranty from M/s BHEL on dt.02.11.12.11 4952 28479 NCR CNB ConventionalWAG7 05-Aug-12CLW16-Aug-12TransformerQLM drop with TF oil splashed through conservator. TF oil DGA found C2H2=6231.35ppm, C2H4=4119.44ppm, CH4=1460ppm, C2H6=256.91ppm, CO2=1093.07ppm, CO=1429.15ppm & H2=2668.38ppm. Oil BDV=31.1KV. TFP Make-BHEL Sl.no.-2033892Informed to CEE/CLW/CRJ with copy to M/s BHEL vide Tech-57, dt 21.08.12.11 4953 22898 SER SRC ConventionalWAP4 11-Nov-11CLW15-Aug-12Traction MotorTM-6 'V' Cone burnt. TM-6 changed. 278 4954 31325 ECR GMO 3-PhaseWAG9 20-Jan-12CLW15-Aug-12Pn. ValveCab-1 side given message brake electronics failed as A-9 defective. Another A-9 valve changed from section in No-57 208 4955 31325 ECR GMO 3-PhaseWAG9 20-Jan-12CLW15-Aug-12MiscellaneousCab-2 Asst. driver side wiper arm with blade defective. Replaced by other wiper arm with blade. 208 4956 31332 ECR GMO 3-PhaseWAG9 18-Feb-12CLW15-Aug-12Pn. ValveAir flow indicator not working both cab due to rubber seating of valve stem assembly open out. Other valve change from section in No-2-01 179 4957 31340 ECR GMO 3-PhaseWAG9 24-Mar-12CLW15-Aug-12MiscellaneousCab-1 LT horn sounding due to diaphragm burst. Another horn change from section. 144 4958 31332 ECR GMO 3-PhaseWAG9 18-Feb-12CLW15-Aug-12Pn. ValveAir flow indicator not working both cab due to rubber seating of valve stem assembly open out. Other valve change from section in No-2-01 179 4959 31340 ECR GMO 3-PhaseWAG9 24-Mar-12CLW15-Aug-12MiscellaneousCab-1 LT horn sounding due to diaphragm burst. Another horn change from section. 144 4960 31340 ECR GMO 3-PhaseWAG9 24-Mar-12CLW15-Aug-12MiscellaneousCabC Asst. driver side wiper blade damage. Replaced by new blade from section. 144 4961 22933 NCR CNB ConventionalWAP4 14-Aug-12CLW14-Aug-12Auxiliary MotorMVSL-2 one phase winding earth & star point open circuit. Make-SH, Sl.No. 13118 & Date of manufacturing 06/2012.MVSL-2 changed & kept on shed floor for warranty replacement.0 4962 22933 NCR CNB ConventionalWAP4 30-Jun-12CLW14-Aug-12Auxiliary MotorDuring testing MVSL-2 smoked. One phase and star point open.Advised to CLW45 4963 28491 ECR MGS ConventionalWAG7 14-Aug-12CLW14-Aug-12RSI blockRSI-2 isolated due to QRSI -2 drop.In shed checked and found one power diode puntured and 6 No HRC fuse melted. 6 No. HRC and one puntured diode changed.0 4964 22933 NCR CNB ConventionalWAP4 14-Aug-12CLW14-Aug-12Auxiliary MotorMVSL-2 one phase winding earth & star point open circuit. Make- SH, Sl. no. 13118& Date of Mfg.-06/2012.Informed to CEE/CLW/CRJ vide Tech-57, dt 16.08.12.0 4965 24616 SR ED ConventionalWAG7 12-Aug-12BHEL13-Aug-12MPFDCSWhile working 56845 pass, while approaching DSPT home signal DJ tripped no pilot lamps glowing and FDCS display showing "Communication of this cab failed.MPCS control card-2 defective (communication). Same replaced and checked, found working normal.1 4966 28479 NCR CNB ConventionalWAG7 05-Aug-12CLW13-Aug-12Auxiliary MotorLoco withdrawn due to TFP oil leakege from MPH terminal casing gasket. Same changed.Gasket changed.Advised to CLW on 16.11.12 by ELS/CNB.8 4967 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12MiscellaneousHT horn not sounding due to diaphragm deformed. Another Diaphragm fitted. 144 4968 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12Aux. converter (BUR)Life sign missing from BUR-1 'CD' slot card defective. Card changed. 144 4969 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12Aux. converter (BUR)Life sign missing from BUR-1 'CD' slot card defective. Card changed. 144 4970 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12Traction converter (SR)Bogie-1 isolate, ASC-2 error MUB GBC, SR2-13 valve set V4 GTO short. Valve set changed. 144 4971 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12Traction converter (SR)Bogie-1 isolate, ASC-2 error MUB GBC, SR2-229 Gate unit defective. Gate unit changed. 144 4972 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12Traction converter (SR)Bogie-1 isolate, ASC-2 error MUB GBC, SR2-229 Gate unit defective. Gate unit changed. 144 4973 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12Traction converter (SR)Bogie-1 isolate, ASC-2 error MUB GBC, SR2-229 Gate unit defective. Gate unit changed. 144 4974 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW13-Aug-12415V  MCB(11-14) interlock of Auxiliary-1 contact for CP-1 MCB sometime not close. New Auxiliary-1 contact changed. 144 4975 31328 ECR GMO 3-PhaseWAG9 03-Feb-12CLW13-Aug-12Angle transmitter/display Unit/SwitchesCab-1 head light dimmer not glowing due to 'ZPRD' switch defective. New 'ZPRD' switch fitted. 192 4976 31328 ECR GMO 3-PhaseWAG9 03-Feb-12CLW13-Aug-12110V MCBSRP-1 MCB Interlock No. (11-14) not making contact. SRP-1MCB Changed.192 4977 22894 SER SRC ConventionalWAP4 25-Sep-11CLW12-Aug-12Pn. PipelineMR pressure dropped for air leakage from electro pneumatic pipe line due to line contactor no. 1, 2, 3 broken from union joint. BA-1 panel EP-1 pipe broken before cut of cock due to pipe line tension. Clamping done on BA-1&2 panel pipe line. 322 4978 22894 SER SRC ConventionalWAP4 25-Sep-11CLW12-Aug-12Pn. PipelineMR pressure dropped for air leakage from electro pneumatic pipe line due to line contactor no. 1, 2, 3 broken from union joint. Checked and found that MR pipe line (coming from Control Reservoir) is broken from union joint before EP -1 C.O.C. So LP could not isolate the pipe line. During checking it was found that there was clamps provided or both side of the pipe and the pipe line was in tension. It could not be matched to each other after the breakage. So it is clear that pipe line was broken in two parts due to tension of pipe line. Same attended.322 4979 24575 NR LDH ConventionalWAG7 21-Dec-11BHEL11-Aug-12ESMONBoth SPM not working & VCD already isolate. Pin no. 34 of 50 pin connector was broken causing both SPM not working & VCD found normal 50 pin mail connector changed & VCD put back in service. MRT-922, saitronic 234 4980 24591 NR LDH ConventionalWAG7 15-Apr-12BHEL11-Aug-12SIVDJ trip , SIV not pickup Inverter PWR assembly & SIBCOS -2000 changed 118 4981 24587 NR LDH ConventionalWAG7 11-Apr-12BHEL10-Aug-12EP ContactorJ-1 not set and its aux interlock not passing supplySetting of aux interlock was adjusted and interlock operating cams were replaced121 4982 24587 NR LDH ConventionalWAG7 01-Apr-12BHEL10-Aug-12EP ContactorSetting of auxiliary interlock was adjusted and interlock operating cam was replaced. Seting of auxiliary interlock adjusted and interlock opearting cam replaced. 131 4983 31330 ECR GMO 3-PhaseWAG9 25-Jun-12CLW09-Aug-12CBC/Draft gear/TSCCab-2 coupler crack. Same changed. 45 4984 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted. Same attended-17 4985 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush. Same attended-17 4986 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12HT/LT cableBA-1, 2, 3 panel power cable rubbing with channel. Same attended-17 4987 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12MiscellaneousTop side of BD cable badly rubbing with hood due to gasket not provided. Same attended-17 4988 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12HT/LT cableCab-1 SB few cables hanging and open condition. Same attended-17 4989 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12RPS/RS/DBRRPS foundation bolt deficient from MPH side to conservator side due to hole not matching. Same attended-17 4990 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12VCDHQVCD sequence wrong. Same attended-17 4991 28490 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12MiscellaneousCab-1 AC not cooling and heating. Only blower working. Cab-2 AC not working (Make Daulat Ram). Same attended by Firm representative-17 4992 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted. Same attended-17 4993 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush. Same attended-17 4994 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12HT/LT cableBA-1, 2, 3 panel power cable rubbing with channel. Same attended-17 4995 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12MiscellaneousTop side of BD cable badly rubbing with hood due to gasket not provided. Same attended-17 4996 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12Vacuum Circuit Breaker (VCB)Two nos. RC damping board for VCB will be provided. Same attended-17 4997 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12RPS/RS/DBRRPS foundation bolt not fitted from MPH side to conservator side due to hole not matching. Same attended-17 4998 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12MiscellaneousBPT-2 checknut deficient. Same attended and fitted-17 4999 28489 SER TATA ConventionalWAG7 25-Aug-12CLW08-Aug-12VCDHQVCD sequence wrong. Same attended.-17 5000 22924 WCR ET ConventionalWAP4 29-May-12CLW07-Aug-12Traction MotorTM-1 armature S.N. RE/ CLW / New, its one balancing weight was broken, which resulted armature showing grounded. Failed TM-1 was received with same loco ex. CLW on dtd. 19/05/12, which failed within 70 days. ---70 5001 22924 WCR ET ConventionalWAP4 29-May-12CLW07-Aug-12Traction MotorTM-1 armature S.N. RE/ CLW / New, its one balancing weight was broken, which resulted armature showing grounded. Failed TM-1 was received with same loco ex. CLW on dtd. 19/05/12, which failed within 70 days. ---70 5002 31330 ECR GMO 3-PhaseWAG9 25-Jun-12CLW07-Aug-12Brake system (E-70/Knorr)Heavy air leakage from E-70 15 No. EP valve due to seal of combined isolating cock & reatracting valve open & deformed. Seal changed. 43 5003 31321 ECR GMO 3-PhaseWAG9 07-Jan-12CLW06-Aug-12Central ElectronicsLife sign missing, FLG/STB/DDA2 Card changed. 212 5004 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12MiscellaneousCab-2 HT horn dull sound. Same attended.-12 5005 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12MiscellaneousCab-2 FP gauge pressure showing 6.4 (0.4 error) showing from cab-1. Same attended.-12 5006 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12Pn. ValveSS-2 not blowing up to 10 Kg/sq.cm.Same attended and adjusted-12 5007 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted.Same attended-12 5008 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush.Same attended.-12 5009 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12HT/LT cableBA-1, 2, 3 panel power cable rubbing with channel.Same attended.-12 5010 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12HT/LT cableTop side of BD cable badly rubbing with hood due to rubber sheet not provided.Same attended.-12 5011 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12Vacuum Circuit Breaker (VCB)Two nos. RC damping board for VCB will be fitted. Same attended.-12 5012 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12MiscellaneousCab-1 AC Control Unit all LED not glowing (Make Daulat Ram). Same attended by firms representative.-12 5013 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12MiscellaneousWater leakage from AC housing and inside and AC assembly hood (Make Daulat Ram). Same attended.-12 5014 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12VCDHQVCD sequence wrong. Same attended.-12 5015 28488 SER TATA ConventionalWAG7 18-Aug-12CLW06-Aug-12VCDHQVCD sequence wrong. Same attended.-12 5016 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted. Same attended.-6 5017 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush. Same attended.-6 5018 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12HT/LT cableBD 1, 2, 3 power cable rubbing with channel due to gasket not provided. Same attended.-6 5019 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12MiscellaneousCTF-1 back side servomotor bucket punchured. Same attended.-6 5020 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12RPS/RS/DBRRPS foundation not fitted from MPH side to conservator side due to hole not matching. Same attended.-6 5021 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12RPS/RS/DBRDBR SB terminal hanging condition.Same attended.-6 5022 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12HT/LT cableTop of BD cable badly rubbing with hood due to gasket not provided.Same attended and gasket provided.-6 5023 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12Vacuum Circuit Breaker (VCB)RC damping for VCB only two nos. board fitted. Two RC damping board will be fitted. Same attended.-6 5024 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12Pn. ValveVEF not working properly. Same attended.-6 5025 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12MiscellaneousBoth cab FP gauge 0.6 difference (Cab-2 0.6 excess). Same attended.-6 5026 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12MiscellaneousCab-2 BC gauge needle jamming condition and not showing pressure.Same attended.-6 5027 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12MiscellaneousBoth Cab BC-1 niddle - 0.5 & BC-2 niddle 0.3 error.Same attended.-6 5028 28482 SER TATA ConventionalWAG7 12-Aug-12CLW06-Aug-12Air Blast Circuit Breaker (DJ)Horse Hair Filter to DJ reservoir flexible pipe old type fitted and gasket damaged condition and jammed pipe hole. Same attended.-6 5029 28474 NCR CNB ConventionalWAG7 23-Jul-12CLW06-Aug-12MiscellaneousCab-1 AC not working due to compressor direction wrong & gas re-charge by M/s SIDWAL representative. Make- SIDWAL, Sl. no. 12B030.All defects attended by firm as per Joint note dt. 06.08.12. Informed to CEE/CLW/CRJ vide Tech-57, dt 11.08.12. 14 5030 30308 ER HWH 3-PhaseWAP7 13-Apr-12CLW05-Aug-12HL/FLCab-2 Head light was not working.Diode pin was in bend condition, same attended.114 5031 31321 ECR GMO 3-PhaseWAG9 07-Jan-12CLW05-Aug-12Traction converter (SR)ASC-2 Fiber optic power fail, ASC side Fiber optic card defective. Card changed. 211 5032 31321 ECR GMO 3-PhaseWAG9 07-Jan-12CLW04-Aug-12415V  MCB(11-14) interlock of Auxiliary-1 contact for OCB-1 MCB permanent open. New Auxiliary-1 contact fitted. 210 5033 31321 ECR GMO 3-PhaseWAG9 07-Jan-12CLW04-Aug-12MiscellaneousCab-2 both side wiper blade damage. Another blade change from section. 210 5034 28474 NCR CNB ConventionalWAG7 30-Jul-12CLW04-Aug-12Traction MotorTM-6 armature band found open.Advised to CLW.5 5035 28474 NCR CNB ConventionalWAG7 14-Aug-12CLW04-Aug-12Traction MotorDuring IC0 inspection TM-6 armature band open. Make-CGL, Armature no. 2108200-276.TM-6 changed. TM-6 armature received against warranty repaired on 17-01-13.-10 5036 22927 WCR ET ConventionalWAP4 27-Jun-12CLW04-Aug-12MiscellaneousL-5 EP valve changed, since sluggish operation. --38 5037 28474 NCR CNB ConventionalWAG7 23-Jul-12CLW04-Aug-12SIVSIV internal fault. ‘U’ phase GDU card defective. GDU card changed by firm on 04.08.12 in shed. Make- AAL (Gen), DOC-06.08.12. Sl. No. OB 180 1107 039. Informed to CEE/CLW/CRJ vide Tech-57, dt 07.08.12.12 5038 28475 NCR CNB ConventionalWAG7 10-Jul-12CLW03-Aug-12SIVSIV internal fault. ‘U’ phase GDU card defective. GDU card changed by firm on 04.08.12 in shed. Make- AAL (Gen), DOC-06.08.12. Sl. No. OB 180 1107 039. -24 5039 28475 NCR CNB ConventionalWAG7 10-Jul-12CLW03-Aug-12SIVSIV internal fault due to "U" phase GDU card defective. Make-AAL (Generic), Sl.No. OV 180 1107 039. GDU card changed by firm on dt.04.08.12.24 5040 22895 SER SRC ConventionalWAP4 08-Oct-11CLW03-Aug-12MPFDCSRB out of order due to C145 stuck up several times. Firm (Stesalit) representative attended the same and found that, Output-15 of Output-1 card related to C145 closing is showing high i.e. giving +110V feed continuously through no operation regarding C145 closing is done. Output -1 card replaced. 300 5041 28445 SCR KZJ ConventionalWAG7 01-May-12CLW03-Aug-12BatteryMU Locos T/O from SR by train no BCN at 10.45hrs, and informed that in trailing Loco 28445/KZJ in dead condition due to battery voltage zero.TS/RU mechanics attended and unable to trace the problem.On examination checked and found all Batteries Run down because of specific Gravity low.All Batteries Replaced with Fully Charged Batteries & initial charging of defective batteries was carried out.94 5042 24601 SR ED ConventionalWAG7 14-Jun-12BHEL02-Aug-12EP ContactorCam type reverser (J1) very hard and stuck up since centre locking cam No. 3 broken and formed grooves against bearing. Three numbers of contact pressure adjusting nuts found fallen from its studs. Inside the actuating cylinder.Reverser changed by firms (Stesalit) representative on 25.8.12.49 5043 22925 WCR ET ConventionalWAP4 12-Jun-12CLW01-Aug-12Battery Charger (CHBA)Battery make Labco, Kolcatta / Mfg. 03/12, (Comm. 05/12), last provided by ELS ET on dtd. 20/06/12. Total voltage found 60 volt. with CCBA fuse. Voltage found less=30 volt (during MCPA working) and specific gravity found 1150 and battery voltage found less=6.69 to 9.44 volt per battery. Failure is due to battery failing causing voltage to go low during run. Battery are under warranty. It is a warranty failure case of battery. --50 5044 22928 CR BSL ConventionalWAP4 01-Aug-12CLW01-Aug-12Auxiliary MotorMVSL-1 CHECKED on S/F found all 03 phase open ckt REPORTED TO FIRM VIDE L. NO. BSL/TRS/S/WTY/MVSL/ SAMAL HARAND DT.01/10/120 5045 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted. Modification to be done.-10 5046 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush.Same attended.-10 5047 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12MiscellaneousCab AC not working (Make Daulat Ram). Firms representative attended.-10 5048 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12HT/LT cableBoth cab SB cable hanging & cable dressing not proper. Same attended.-10 5049 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12HT/LT cableBA-1, 2, 3 panel power cable rubbing with channel due to gasket not provided.Same attended.-10 5050 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12GR/RGR/CGRCGR 2, 3 to RGR connection short link over large.Same attended.-10 5051 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12GR/RGR/CGRCGR-3 busbar (top side) tracking with base. Same attended.-10 5052 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Traction MotorV' cone cutting of armature are not done.Same to be attended-10 5053 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12MiscellaneousPneumatic panel side SB terminal block several seperators broken condition and all terminal block studs are loose.Same attended.-10 5054 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Vacuum Circuit Breaker (VCB)Two nos. RC damping board for VCB will be fitted.Same fitted.-10 5055 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12HT/LT cableTop side of BD cable badly rubbing with hood due to rubber sheet not provided.Same attended.-10 5056 28486 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12MiscellaneousOil leakage from A33 side Radiator dummy bolt, conservator 3-way cock, MPH dummy plug.Same attended.-10 5057 22898 SER SRC ConventionalWAP4 11-Nov-11CLW01-Aug-12Bogie & its Mech. equip.Axle Box-10 (L/S) primary spring last coil broken. Spring changed. 264 5058 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted.Same attended-10 5059 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush.Same attended.-10 5060 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12MiscellaneousOil leakage from A33 bushing, GR neck back side inspection cover, GR 3-way cock. Oil leakage from different bushing and gasket area.Same attended.-10 5061 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12GR/RGR/CGRCGR 2, 3 to RGR connection short link very large.Same attended and short link provided.-10 5062 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12HT/LT cableBA-1, 2, 3 power cable pressed & rubbing with channel due to rubber sheet not provided.Same attended.-10 5063 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12TransformerTFP conservator 3-way cock pipe line crack and continuous oil leakage and oil spread.Same attended and TFP conservator 3-way cock pipe line changed.-10 5064 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12HT/LT cableSB 1, 2 some cables hanging and open condition.Same attended.-10 5065 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12MiscellaneousTK panel inside bulb fixation plate loosely fitted.Same attended.-10 5066 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Vacuum Circuit Breaker (VCB)Two nos. RC damping board for VCB will be fitted.Same attended.-10 5067 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12MiscellaneousGrease not entered in CE End shield and earthing cables are not fitted.Same attended.-10 5068 28485 SER TATA ConventionalWAG7 11-Aug-12CLW01-Aug-12Traction MotorV' cone cutting of armature are not done.Same attended.-10 5069 31335 ECR GMO 3-PhaseWAG9 01-Mar-12CLW01-Aug-12415V  MCB(11-14) interlock of Auxiliary-1 contact for CP-1 & CP-2 MCB permanent. New Auxiliary-1 contact fitted with CP-1 & CP-2 MCB. 153 5070 22932 NCR CNB ConventionalWAP4 25-Aug-12CLW31-Jul-12MiscellaneousLoco failed in ASN Division before reaching to NCR & commissioning. Attended by MGS shed found PG Sensor defective same changed.PG Sensor changed by MGS Shed. Advised to CLW on 29-08-2012-25 5071 24571 NR LDH ConventionalWAG7 08-Nov-11BHEL31-Jul-12Axle BoxDuring IC inspection FC found excess axle box no. 4 1. Axle box thrower found overheated, matallic pieces cut & melted on it. 2. Thrower mounted on journal over heated & melted metallic piece deposited on its seat. 3. Both rollar bearing defective due to insertion of matallic pieses. Axle with axle boxes has been replaced with new by ELS/LDH266 5072 22880 SER SRC ConventionalWAP4 28-May-11CLW30-Jul-12MiscellaneousHeavy flashing from OHE at km no- 665/31 on crossover due to steady arm bent causing PT-2 entangled and broken. Same secured by TRD staff then worked with leading panto. PT-2 pan and steady arm changed.429 5073 22894 SER SRC ConventionalWAP4 25-Sep-11CLW30-Jul-12ESMON"Both SPM not working. Found SPM-2 showing no signal from RCI. SPM-1 stuck up at 40 KMPH. SPM Make- Laxven" SPM-1 changed. 309 5074 28440 SCR KZJ ConventionalWAG7 21-Apr-12CLW30-Jul-12BatteryLP informed that while rolling into AKP DJ tripped in trailing loco no 28440/KZJ. on examination found battery voltage between 30 to 50 V only in loco no 28440.found all Batteries Run down because of specific Gravity low.Firm advised & replaced with fully charged batteries.100 5075 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW30-Jul-12415V  MCB(11-14) interlock of Auxiliary-1 contact for TMB-2 MCB permanent open. New Auxiliary-1 contact fitted with TMB-2 MCB. 185 5076 31332 ECR GMO 3-PhaseWAG9 18-Feb-12CLW30-Jul-12Angle transmitter/display Unit/SwitchesCab-2 head light dimmer not glowing due to 'ZPRD' switch cam open. ZPRD' switch of Cab-2 changed. 163 5077 31332 ECR GMO 3-PhaseWAG9 18-Feb-12CLW29-Jul-12TM/MR Scavenge motorTMS 1 Bonded. Phase to earth but not Phase to phase. TMS-1 changed. 162 5078 31332 ECR GMO 3-PhaseWAG9 18-Feb-12CLW29-Jul-12415V  MCB(11-14) interlock of Auxiliary-1 contact for CP-1 MCB permanent open. New Auxiliary-1 contact for CP-1 MCB fitted. 162 5079 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW29-Jul-12Traction converter (SR)Bogie-2 off, NSC2 CGP, SR2 12/1 valve set V5 diode short. Valve set changed. 184 5080 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW29-Jul-12Aux. converter (BUR)BUR-2 inverter over current, 'S' phase GDU defective. GDU changed. 184 5081 31332 ECR GMO 3-PhaseWAG9 18-Feb-12CLW29-Jul-12MiscellaneousCab-1 both side wiper not working due to its blade damage. Replaced by old blade. 162 5082 28441 SCR KZJ ConventionalWAG7 22-Apr-12CLW29-Jul-12BatteryLoco pilot reported from NDB (Nadurbar) station VCB tripped with QSIT and external and internal fault message on MPFDS.Loco checked and unable to overcome the trouble ,hence Loco arrived shed checked and found all Batteries Run down because of specific Gravity low.All Batteries Replaced with Fully Charged Batteries 98 5083 22924 WCR ET ConventionalWAP4 29-May-12CLW29-Jul-12MiscellaneousCTF-1 servomotor defective. --61 5084 31350 SECR BIA 3-PhaseWAG9 30-Jul-12CLW29-Jul-12Sensor (FDU, Speed, Pressure, Temp. OHE/ Voltage)Loco tested found Bogie-2 isolated with fault message ASC2 error PS fault storage GBC (130D). checked found fiber optic cable from card no. 635 to 228/7 db value 46.15 hence fiber optic cable replaced. Fiber optic cable defective same replaced. -1 5085 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted.Same attended.-8 5086 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush.Same attended.-8 5087 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12VCDVCD not working.Same attended.-8 5088 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12MiscellaneousNegative bonding present.Same attended.-8 5089 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12MiscellaneousCab 1 & 2 AC not cooling (Make Sidwal).Same attended by firms representative.-8 5090 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12TransformerOil leakage from A0 bushing, TFP conservator 3-way cock and Radiator dummy bolt.Same attended.-8 5091 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12MiscellaneousBD board top gasket not provided due to MPCS cable rubbing with hood and bottom side gasket also not provided.Same attended.-8 5092 28484 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12HT/LT cableBD backside cable dressing not proper and cable rubbing.Same attended.-8 5093 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12Bogie & its Mech. equip.Non-modified tiebar and slack adjuster fitted.Same attended.-8 5094 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12Bogie & its Mech. equip.Iron bush provided in equalizing and compensating beam in place of polymide bush.Same attended.-8 5095 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12MiscellaneousBoth cabs AC not working (Make: Daulat Ram)Same attended by firms representative.-8 5096 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12Pn. PipelineIn BA1 Panel common pipeline (of L/C, S/C, Reverser & CTF) blow hole.Same attended.-8 5097 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12DC-DC Converter/HL/FLDC-DC converter all indicator light glowing in both position.Same attended.-8 5098 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12MiscellaneousMPH to conservator 3-way cock copper pipe having no clamp and pipe crack.Same attended.-8 5099 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12TransformerOil leakage from different places of TFP bushing and gasket area.Same attended.-8 5100 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12SwitchWhen HPAR on '1' position then L/C close in L.T. Same attended.-8 5101 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12HT/LT cableBD backside cable dressing not proper. BD top side MCP cable rubbing with inside hood due to rubber sheet not provided. Same attended and rubber sheet provided-8 5102 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12HT/LT cableSB-1 and SB-2 cable dressing not in proper way. Same attended.-8 5103 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12HT/LT cableBD front side few cables are in hanging condition. Same attended.-8 5104 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12MiscellaneousTK panel inside spot light base loose condition. Same attended.-8 5105 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12HT/LT cableBA-1, 2, 3 power cable press & rubbing with frame. Same attended.-8 5106 28483 SER TATA ConventionalWAG7 05-Aug-12CLW28-Jul-12Traction MotorTM-5 locking pin hole dummy. Same attended.-8 5107 28455 SER TATA ConventionalWAG7 27-May-12CLW27-Jul-12MiscellaneousOne wiper blade arm broken.Same attended61 5108 28455 SER TATA ConventionalWAG7 27-May-12CLW27-Jul-12Pn. ValveCab-2 A9 defective.Same attended61 5109 28455 SER TATA ConventionalWAG7 27-May-12CLW27-Jul-12Traction MotorTM-1 commutator slight rubbing found (one place) so rocker ring turning continued.Same attended61 5110 28455 SER TATA ConventionalWAG7 27-May-12CLW27-Jul-12EM ContactorS-11 roller broken.Same attended61 5111 28457 SER TATA ConventionalWAG7 27-May-12CLW27-Jul-12Vacuum Circuit Breaker (VCB)VCB (AREAVA) pressure regulator not working satisfactorily as pressure decreases from 5.2 Kg/sq.cm to 4.6 Kg/sqcm.Same attended61 5112 28457 SER TATA ConventionalWAG7 19-May-12CLW27-Jul-12MiscellaneousCab-1 BC gauge defective.Same attended69 5113 28457 SER TATA ConventionalWAG7 19-May-12CLW27-Jul-12Pn. ValveAFI not working. AFMV defective.Same attended69 5114 22891 SER SRC ConventionalWAP4 03-Sep-11CLW27-Jul-12Pn. Pipeline"MR & BP pressure dropped due to pneumatic pipe line of MR-3 supply open from port no. 14 at pneumatic panel. During checking found that at Pneumatic panel (Tri plate, make SIL) port no; 14 the incoming MR3 pipe line for BP charging is come out from its ferrule. " "All the pipe lines connection at the Tri plate panel which are connected by ferrule are replaced by Male-Female union sockets. " 328 5115 22891 SER SRC ConventionalWAP4 03-Sep-11CLW27-Jul-12Pn. PipelineMR & BP pressure dropped due to pneumatic pipe line of MR supply open from port no. 14 at pneumatic panel.Loco checked found that at Pneumatic panel (Tri plate, make SIL) port no; 14 the incoming MR3 pipe line for BP charging is come out from its ferrule. Its check-nut, ferrule check-ring and ferrule was fitted with the pipe line attached with Pn. Panel but the Cu pipe line ¾” was came out. It is due to looseness of ferrule at crimping point. An extra support was fitted at the tri plate panel. The foundation of the panel was good condition.All the pipe lines connection at the Tri plate panel which are connected by ferrule are replaced by Male-Female union sockets.328 5116 28443 SCR KZJ ConventionalWAG7 10-May-12CLW27-Jul-12BatteryLP informed that in trailing loco 28443 battery voltage between 30 to 50 V only. checked found MPFDS message " Configuration mismatch and loco cannot work". Hence mu splitted.On examination checked and found all Batteries Run down because of specific Gravity low.Firm advised & batteries were replaced with overhauled one's & initially charging & capacity test for defective batteries was done. 78 5117 24607 SR ED ConventionalWAG7 26-Jul-12BHEL26-Jul-12RSI blockIn RSI-1, one 2 M. Ohms 100W resistance burnt, since capacitor connection was wrong.BHEL make RSI.0 5118 24607 SR ED ConventionalWAG7 26-Jul-12BHEL26-Jul-12DC-DC Converter/HL/FLDC-DC converter was not working.Output connections were reverse and fuse was blown.0 5119 24607 SR ED ConventionalWAG7 26-Jul-12BHEL26-Jul-12BatteryBattery No. 3 +ve lug found melted.Battery changed.0 5120 28454 SER TATA ConventionalWAG7 29-May-12CLW26-Jul-12Auxiliary MotorMCPA oil leakage.Same attended58 5121 28454 SER TATA ConventionalWAG7 29-May-12CLW26-Jul-12MiscellaneousOne wiper blade arm brokenSame attended58 5122 28454 SER TATA ConventionalWAG7 29-May-12CLW26-Jul-12Pn. ValveAFI not working. AFMV defective.Same attended58 5123 28454 SER TATA ConventionalWAG7 29-May-12CLW26-Jul-12MiscellaneousAll linkage pin provided with spacer. So split cotter loose.Same attended58 5124 28454 SER TATA ConventionalWAG7 29-May-12CLW26-Jul-12EM ContactorL5 roller broken.Same attended58 5125 28456 SER TATA ConventionalWAG7 28-May-12CLW26-Jul-12MiscellaneousAll linkage pin provided with spacer. So split cotter loose.Same attended59 5126 28456 SER TATA ConventionalWAG7 28-May-12CLW26-Jul-12Traction MotorTM-5 flashed.Same attended59 5127 28446 SER BNDM ConventionalWAG7 22-May-12CLW26-Jul-12DC-DC Converter/HL/FLOne position not working. Make- Signotron, Sr. No.- 11075670 Report sent to M/s Signotron 65 5128 28452 SER BNDM ConventionalWAG7 23-May-12CLW26-Jul-12EP ContactorRoller broken. Make-CLW, Sr. No.- 11/12/0450 Report sent to CLW/CRJ 64 5129 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW26-Jul-12415V  MCB(11-14) interlock of Auxiliary contact for CP-2 MCB permmanent open. New Auxiliary-1 contact for CP-2 MCB fitted. 179 5130 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW26-Jul-12TM/MR Scavenge motorTMS 2 Bonded. All phase short to ground. TMS-2 changed. 179 5131 31336 ECR GMO 3-PhaseWAG9 20-Mar-12CLW24-Jul-12HL/FLCab-1 Flasher light not glowing, Top LED unit defective. Unit changed. 126 5132 24598 NR LDH ConventionalWAG7 27-Mar-12BHEL24-Jul-12Vacuum Circuit Breaker (VCB)ICDJ due to VCB feedback failed. VCB defective VCB changed 119 5133 28478 NCR CNB ConventionalWAG7 12-Jul-12CLW23-Jul-12MiscellaneousCab-1 AC not working. Compressor direction wrong. Condenser motor direction wrong. Cable no. 1AC-966 break between AC change over to cab-1 AC panel. Make-Sidwal, Sl.no. – 12B042.All defects attended by firm as per Joint note dt. 28.07.12. Informed to CEE/CLW/CRJ vide Tech-57, dt 27.07.12. 11 5134 28471 NCR CNB ConventionalWAG7 11-Jul-12CLW23-Jul-12MiscellaneousBoth cab AC not working. Cab-2 AC unit 14 pin connector pin short circuited due to sleeve came out. Sleeve changed & heater contactor control connection interchanged by firm being wrongly connected. Make-DRI, Sl.no.-83/86Informed to CEE/CLW/CRJ vide Tech-57, dt 14.08.12.12 5135 24605 SR ED ConventionalWAG7 10-Jul-12BHEL20-Jul-12Bogie & its Mech. equip.Slack adjuster damaged.Slack adjuster changed.10 5136 24580 NR LDH ConventionalWAG7 16-Feb-12BHEL19-Jul-12Bogie & its Mech. equip.W/No. 5 outer helical spring broken W/No. 5 outer helical spring changed 154 5137 28476 NCR CNB ConventionalWAG7 10-Jul-12CLW18-Jul-12MiscellaneousBoth cab AC not working. Cab-1 AC unit coupler loose & cab-2 compressor direction reverse. Joint made with firm on 12.07.12. AC Make-DRI, Sl. noInformed to CEE/CLW/CRJ vide Tech-57, dt.18.07.12.8 5138 31322 ECR GMO 3-PhaseWAG9 01-Jan-12CLW18-Jul-12Traction converter (SR)ASC-1 GBC, ASC-1 Fiber optic card defective. ASC-1 Fiber optic card changed. 199 5139 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW17-Jul-12Sensor (FDU, Speed, Pressure, Temp. OHE/ Voltage)Bogie-1 off, SLG-1 Disturbance in TR-1 temperature sensor, Temperature sensor defective. TR-1 Temperature sensor changed. 117 5140 22927 WCR ET ConventionalWAP4 27-Jun-12CLW17-Jul-12VCDCab-1 AC of M/s. Daulatram was defective. Informed CEE (L & S) CLW on dtd. 24/07/12 vide L.No. ET/TRS/PPIO/30/152. 20 5141 28476 NCR CNB ConventionalWAG7 11-Jul-12CLW16-Jul-12Traction MotorDuring IC0 TM-3 armature band found open. TM-3 changed.Advised to CLW on 20-07.2012 by ELS/CNB.5 5142 22925 WCR ET ConventionalWAP4 12-Jun-12CLW16-Jul-12Traction MotorFound TM-5 armature No.RE/CLW/5046, balancing weight broken and touch with armature coil, causing QOP-2 dropping. Informed CEE (L & S) CLW on dtd. 22/08/12 vide L.No. ET/TRS/PPIO/30/166. 34 5143 22927 WCR ET ConventionalWAP4 27-Jun-12CLW16-Jul-12VCDVCD main unit of M/s. Stesalit was internal defective. Informed CEE (L & S) CLW on dtd. 24/07/12 vide L.No. ET/TRS/PPIO/30/152. 19 5144 31334 ECR GMO 3-PhaseWAG9 24-Feb-12CLW16-Jul-12Angle transmitter/display Unit/SwitchesCab-2 BPFA working but its yellow LED not glowing due to defective. New Yellow LED fitted. 143 5145 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW15-Jul-12415V  MCB(11-14) interlock of Auxiliary of Auxiliarey contact for CP-1 MCB permanent open. New Auxiliary-1 contact for CP-1 MCB fitted. 170 5146 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW15-Jul-12Angle transmitter/display Unit/SwitchesCab-1 'BPPB" working but its Red LED not glowing due to defective. New Red LED fitted. 170 5147 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW15-Jul-12Angle transmitter/display Unit/SwitchesCab-2 BPFA working but its RED LED not glowing due to defective. New Red LED fitted. 170 5148 31324 ECR GMO 3-PhaseWAG9 27-Jan-12CLW15-Jul-12415V  MCB(11-14) interlock of Auxiliary-1 contact for CP-2 MCB permanent open. New Auxiliary-1 contact for CP-2 MCB fitted. 170 5149 31324 ECR GMO 3-PhaseWAG9 24-Jan-12CLW14-Jul-12Traction motorTM-1 Pinion shaft broken & Rotor defective. TM changed.172 5150 22927 WCR ET ConventionalWAP4 27-Jun-12CLW13-Jul-12Battery Charger (CHBA)AAL make CHBA defective. --16 5151 28419 SECR BIA ConventionalWAG7 11-Feb-12CLW13-Jul-12HT/LT cableCab-1 AC control unit cable no 967 insulation cut and getting earth with foot plate ALP side. Loco failed due to improper routing of AC cable. Incoming cable of AC control unit provided near foot plate of ALP without proper protection caused damaged to cable and got earth. Same cable insulation provided and squared properly after attention loco tested and found normal.153 5152 28476 NCR CNB ConventionalWAG7 11-Jul-12CLW13-Jul-12Traction MotorTM-3 commutator side glass band open. Make-CLW, St. no. 12471.Informed to CEE/CLW/CRJ vide Tech-57, dt 20.07.12.2 5153 28476 NCR CNB ConventionalWAG7 11-Jul-12CLW12-Jul-12MiscellaneousCab-1 AC not working. Cab-1 AC coupler not passing supply, resulting compressor not working. Cab-1 AC coupler pin changed by M/s DRI, but still not working. Again 02 nos coupler pin changed, but AC not proper working due to less gas. Make-DRI, Sl.no. 80.All defects attended by firm as per Joint note dt. 28.07.12. Informed to CEE/CLW/CRJ vide Tech-57, dt 26.07.12. 1 5154 31333 ECR GMO 3-PhaseWAG9 28-Feb-12CLW12-Jul-12Central ElectronicsFLG-2 Life sign missing. FLG card changed. 135 5155 28443 SCR KZJ ConventionalWAG7 10-May-12CLW11-Jul-12Roof Equipments misc.Loco Pilot reported SIV external fault with CHBA-FT message.Checked and found,CHBA working normal, further checked A/C unit Earth fault.Firm advised & found AC unit internal cables burnt condition.62 5156 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW10-Jul-12Pn. Pipe lineCab-1 BP angle cock deficient due to CRO. Angle cock changed. 110 5157 22891 SER SRC ConventionalWAP4 03-Sep-11CLW09-Jul-12Bogie & its Mech. equip.Axle Box-3 primary spring broken. Spring changed. 310 5158 28430 NCR CNB ConventionalWAG7 22-Mar-12CLW08-Jul-12Control CircuitHT compartment light not glowing. Wire no. CC-220 & DD-220 not passing through driver desk coupler from BL2LM to BD.-108 5159 28473 NCR CNB ConventionalWAG7 04-Jul-12CLW04-Jul-12MiscellaneousBoth cab AC not working. AC change over switch broken.Cab-1 AC control panel connection wrong as loop was not provided, resulting relay for compressor not working. QSIT drop when cab-2 AC put ‘ON’ due to Wire of AC-2 control panel earthed. Make-Sidwal, Sl. no. 12B097 & 12B066.All defects attended by firm representative as per Joint note dt. 21.07.12. Informed to CEE/CLW/CRJ vide Tech-57, dt 30.07.12. 0 5160 24602 SR ED ConventionalWAG7 04-Jul-12BHEL04-Jul-12ESMONIn stesalit make SPM, data not recording and unable to input the parameters and at times.Still problems repeats often.0 5161 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW04-Jul-12Central ElectronicsFDU light not glowing. FDU changed. 157 5162 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW04-Jul-12Oil cooler blower unitOCB-2 Bonded. DE side stator winding flashed. OCB-2 changed. 157 5163 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW04-Jul-12MiscellaneousTE/BE meter not possible to reset in 'O' position. TE/BE meter repaired by shed. 157 5164 31323 ECR GMO 3-PhaseWAG9 07-Jan-12CLW04-Jul-12Machine room blowerMCB tripped. Meggar valve ok but winding resistance difference. MRB-2 changed. 179 5165 31323 ECR GMO 3-PhaseWAG9 07-Jan-12CLW03-Jul-12Aux. converter (BUR)BUR-2 input fuse blown. Fuse changed. 178 5166 31323 ECR GMO 3-PhaseWAG9 07-Jan-12CLW03-Jul-12Aux. converter (BUR)In GG-2 one GTO fixation bolt broken. GG module changed. 178 5167 31325 ECR GMO 3-PhaseWAG9 20-Jan-12CLW02-Jul-12Roof equipment/PantoPT-1 broken due to external hitting (hitting mark as Pantopan) Pantograph changed. 164 5168 22896 SER SRC ConventionalWAP4 15-Oct-11CLW02-Jul-12ESMON"SPM-2 display not working. SPM-2 display showing hazy. SPM Make- Laxven" SPM-2 changed.261 5169 31341 SER TATA 3-PhaseWAG9 04-Apr-12CLW02-Jul-12Sensor (FDU, Speed, Pressure, Temp. OHE/ Voltage)Traction Bg-1 isolate, LSFI continious glowing.VCD found normal. TM-6 temperature sensor defective, one number thermostat wire was open circuit, same wire is attended in loco 31341.89 5170 28456 SER TATA ConventionalWAG7 22-May-12CLW02-Jul-12Battery Charger (CHBA)Sometime LSCHBA not extinguish wkg. Loco arrived to shed on 01.07.12, Loco checked and above said problem was not experienced. On 05.07.12 during testing, found LSCHBA not extinguish and CP not working by BLCP/BLCPD as the supply from QCON relay was not available which is coming from SIV. Same was informed to firm on 05.07.12. 41 5171 22924 WCR ET ConventionalWAP4 29-Nov-12CLW30-Jun-12Traction MotorFound armature No.RE 77/CLW 5046, balancing weight broken and touch with armature coil, causing QOP-2 dropping. Informed CEE (L & S) CLW on dtd. 25/07/12 vide L.No. ET/TRS/PPIO/30/154. -152 5172 22893 SER SRC ConventionalWAP4 17-Sep-11CLW30-Jun-12ESMON"Both SPM not working. Display working, Power supply ok but SPM not working. SPM Make- Laxven" SPM-1 changed. 287 5173 24589 NR LDH ConventionalWAG7 22-Feb-12BHEL30-Jun-12Axle BoxMVMT2 having abnormal sound Motor Changed129 5174 31315 ECR GMO 3-PhaseWAG9 10-May-12CLW29-Jun-12Bogie & its Mech. equip.Traction bar-2 02 nos. bolt broken. Attended at BIA shed 50 5175 31331 ECR GMO 3-PhaseWAG9 29-Jun-12CLW28-Jun-12Traction converter (SR)NSC 1+2 error calibration test, L slot SR card defective. Card changed. -1 5176 31331 ECR GMO 3-PhaseWAG9 29-Jun-12CLW28-Jun-12Traction converter (SR)NSC 1+2 error calibration test, L slot SR card defective. Card changed. -1 5177 31331 ECR GMO 3-PhaseWAG9 29-Jun-12CLW28-Jun-12Traction converter (SR)NSC 1+2 error calibration test, L slot SR card defective. Card changed. -1 5178 22894 SER SRC ConventionalWAP4 25-Sep-11CLW28-Jun-12Bogie & its Mech. equip.Axle Box-7 primary spring broken. Spring changed at BSL. 277 5179 24596 NR LDH ConventionalWAG7 14-Mar-12BHEL28-Jun-12Axle BoxAxle failed in UST 1. Wheel & axle with racer 04 2. distance piece 02 nos. and thrower 02 nos. Axle changed 106 5180 28471 NCR CNB ConventionalWAG7 27-Jun-12CLW27-Jun-12MiscellaneousBoth cab AC not working. Change over MCB base broken causing supply not passing as per joint note with firm dt. 10.07.12. AC Make-DRI, Sl. no. 83 & 96 DOC- 08.06.12. MCB changed by firm. Informed to CEE/CLW/CRJ vide Tech-57, dt.07.07.12.0 5181 28471 NCR CNB ConventionalWAG7 27-Jun-12CLW27-Jun-12MPFDCSLoco trip with QSIT drop when HMCS operated on notches and no message regarding QD & Q-20 relay on display. MPCS un-modified Input & out put cards were provided at CLW. MPCS make-Stesalit, Sl. no.-B61211570, DOC-08.06.12.Informed to CEE/CLW/CRJ vide Tech-57, dt.07.07.12.0 5182 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW27-Jun-12415V  MCBAuxiliary-1 interlock (11-14) permanent open of SR oil pump-1 MCB. New Auxiliary-1 interlock of SR oil pump-1 fitted. 150 5183 31337 ECR MGS 3-PhaseWAG9 22-Mar-12CLW27-Jun-12Pn. ValvePiston assembly seal open out So, EP relay valve 15 leaking heaving. Another E-70 fitted and defective kept for warranty attention. 97 5184 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW26-Jun-12MiscellaneousCab-1 'BPFA' switch not glowing due to its LED defective. New BPFA switch fitted in Cab-1. 96 5185 31337 ECR GMO 3-PhaseWAG9 22-Mar-12CLW26-Jun-12Traction converter (SR)Life sign missing, NSC card defective. NSC card changed. 96 5186 31333 ECR GMO 3-PhaseWAG9 28-Feb-12CLW26-Jun-12Aux. converter (BUR)Life sign missing from HBB-1, CD slot SB card defective. CD' slot SB card changed. 119 5187 24596 NR LDH ConventionalWAG7 14-Mar-12BHEL26-Jun-12Axle BoxAxle Box no 4 failed in ultra sonic testing Axle changed104 5188 24596 NR LDH ConventionalWAG7 14-Mar-12BHEL26-Jun-12Axle BoxAxle Box no 4 failed in ultra sonic testing Axle changed104 5189 22896 SER SRC ConventionalWAP4 15-Oct-11CLW25-Jun-12ESMON"SPM-1 display not working. SPM Make- Laxven" SPM-1 changed. 254 5190 31333 ECR GMO 3-PhaseWAG9 28-Feb-12CLW25-Jun-12Bogie & its Mech. equip.Spheri block damaged. New Knorr vertical damper fitted. 118 5191 31333 ECR GMO 3-PhaseWAG9 28-Feb-12CLW25-Jun-12Bogie & its Mech. equip.Spheri block damaged. New Knorr vertical damper fitted. 118 5192 31330 ECR GMO 3-PhaseWAG9 25-Jun-12CLW24-Jun-12Central ElectronicsFLG-2 Life sign missing. FLG card changed. -1 5193 24594 SR ED ConventionalWAG7 14-Jun-12BHEL24-Jun-12HT/LT cableTM-5 'AA' & 'FF' insulation found perished due to excess tightness at bogie cleat.Loco lifted and attended.10 5194 22892 SER SRC ConventionalWAP4 11-Sep-11CLW23-Jun-12Bogie & its Mech. equip.Axle Box-8 Primary Spring No. 16 broken. Spring changed at BSL. 286 5195 28432 NCR CNB ConventionalWAG7 04-Mar-12CLW23-Jun-12Compressor/ExhausterCP-1 isolate due to safety valve permanent air leakage as HP valve center head gasket burst. Make-Panesar, CP-1 no. 131, MCP no. KJAM 0953.CP HP valve center head gasket changed by firm.111 5196 22925 WCR ET ConventionalWAP4 12-Jun-12CLW23-Jun-12Control CircuitBattery run down due to CHBA was not charging the battery, since at HBA switch connection negative wire No. 006 was uncoupled from HBA, due to poor crimping of lug. Long sleeve was provided in this cable. This loco was arrived ex. CLW in Jun-12, which failed within 11 days. --11 5197 28432 NCR CNB ConventionalWAG7 04-Mar-12CLW23-Jun-12MiscellaneousBoth cab AC not working. Phase 2HAC 967 at switch board & change over switch came out. M/s DRI checked the loco found Compressor MCB ‘off’ (32 Amp.) in control panel ,control panel coupler loose & 110 volt AC wire no. 58 loose due to thimble came out. Make- DRI.All defects attended by firm representative as per Joint note dt. 26.06.12. Informed to firm vide Tech-57111 5198 28432 NCR CNB ConventionalWAG7 04-Mar-12CLW23-Jun-12Compressor/ExhausterCP-1 isolate. CP-1 isolate due to safety valve permanent air leakage. HP valve centre head gasket burst. Make- Panesar CP-1 no.- 131, MCP-1 no. KJAM 0953, DOC-20.03.12. Informed to firm vide Tech-122,dt. 27.06.12.111 5199 31330 ECR GMO 3-PhaseWAG9 25-Jun-12CLW22-Jun-12Pn. ValveBoth NRV rusted and leakage. Both NRV flower changed. -3 5200 31336 ECR GMO 3-PhaseWAG9 20-Mar-12CLW21-Jun-12TM/MR Scavenge motorBonded-All phase earthed. (C ) TMS-1 changed. 93 5201 31321 ECR GMO 3-PhaseWAG9 07-Jan-12CLW21-Jun-12Transformer/ Converter oil pumpAbnormal sound-DE/side bearing cage broken. 4306/SKF/ITALY (N/M) SRP-1 changed. `166 5202 31321 ECR GMO 3-PhaseWAG9 07-Jan-12CLW21-Jun-12Oil cooler blower unitBonded-All phase earthed. (C ) OCB-2 changed. 166 5203 22896 SER SRC ConventionalWAP4 15-Oct-11CLW21-Jun-12MiscellaneousThere is spot of water leakage at different places on Switch board, TK Panel, BD Panel Cover. Water was entered through the roof-joint of loco during heavy rain on run. No rubber sheath was provided on it. The water was fallen on HVSL-1 switch, HVRH switch and C106 contact and among them the HVSL-1 burnt due to high voltage (380v). Others were having only 110v. MVSL-1 meggered, found normal. HVSL-1 Make: SiemensThe switch was changed. All other switches were checked.250 5204 28441 SCR KZJ ConventionalWAG7 30-Apr-12CLW21-Jun-12Auxiliary MotorDuring TI in FS/BZA checked and found MVRH impeller touching body,hence loco moving dead to home shed for attention. checked found Impeller rubbing with duct. MVRH replaced with Overhauled one & firm being advised of this failure.52 5205 30270 CR AQ 3-PhaseWAP7 09-Jan-11CLW20-Jun-12Oil cooler blower unitRadiator leakage detected during schedule.CLW advised528 5206 31274 CR AQ 3-PhaseWAG9 05-Dec-10CLW19-Jun-12Central ElectronicsCP 1 continous on. URB 512 card no. 0909299 make CGL defectiveCard sent to firm for warranty replacement on 19/6/12562 5207 24581 NR LDH ConventionalWAG7 16-Feb-12BHEL19-Jun-12CBC/Draft gear/TSCDraft gear defective due to sliding plates broken same changed 124 5208 22855 SER SRC ConventionalWAP4 02-Jan-11CLW19-Jun-12Transformer"a7-a8 bushing of TFP open circuit. After core lifting of TFP found at a8 bushing the busbar inside the TFP is cracked at the connecting point. TFP make - TRIBHUWAN" "TFP changed. Later firm's representative changed the cracked busbar." 534 5209 31340 ECR GMO 3-PhaseWAG9 24-Mar-12CLW19-Jun-12Central ElectronicsFLG-2 Life sign missing. FLG card defective. 87 5210 31326 ECR GMO 3-PhaseWAG9 28-Jan-12CLW18-Jun-12415V  MCB(11-14) Interlock not close when SR oil pump 1+2 V. 'ON' MCB. Auxiliary contactor of SR oil pump 1+2 new fitted. 142 5211 31326 ECR GMO 3-PhaseWAG9 28-Jan-12CLW18-Jun-12415V  MCB(11-14) Interlock not close when SR oil pump 1+2 V. 'ON' MCB. Auxiliary contactor of SR oil pump 1+2 new fitted. 142 5212 31326 ECR GMO 3-PhaseWAG9 28-Jan-12CLW18-Jun-12415V  MCB(11-14) Interlock not close when SR oil pump 1+2 V. 'ON' MCB. Auxiliary contactor of SR oil pump 1+2 new fitted. 142 5213 22926 WCR ET ConventionalWAP4 29-Jun-12CLW18-Jun-12ESMONMaster SPM mother board was flashed & 50 pin connector was defective. Informed CEE (L & S) CLW on dtd. 26/06/12 vide L.No. ET/TRS/PPIO/30/124. -11 5214 24601 SR ED ConventionalWAG7 14-Jun-12BHEL18-Jun-12ESMONIn stesalit make SPM data is not getting recorded, Cab-2 SPM not working.After attention also still problems repeats often.4 5215 22878 SER SRC ConventionalWAP4 13-May-11CLW16-Jun-12Bogie & its Mech. equip.Bolster-2 approx. 4" crack below Centre Pivot bowl.Bolster changed.400 5216 30050 WR BRC 3-PhaseWAP5 28-Mar-12CLW14-Jun-12Traction converter (SR)Traction bogie no.1 isolated for disturbance in con-1 (Traction bogie no.2 already isolated ex BCT/WR), LP put MCE off/on but not succeed. On checking at BRC shed, M/s BTIL make Gate Unit cards GVA587 of Traction Coverter-1 found defective. M/s BTIL make Gate Unit cards GVA587 of Traction Converter-1 failed under warranty. Same replaced by firm under warranty obligations.78 5217 30050 WR BRC 3-PhaseWAP5 28-Mar-12CLW14-Jun-12Traction motorTraction bogie no.1 isolated for disturbance in con-1 (Traction bogie no.2 already isolated ex BCT/WR), LP put MCE off/on but not succeed. R/Engine given. At BRC shed, found M/s CGL/Bhopal make traction motor (TM4) defective. The firm M/s CGL rep jointly checking the failed TM and found IR value ‘0’. M/s CGL/Bhopal make traction motor failed under warranty. Same repaired by the firm under warranty obligations.78 5218 24610 NR LDH ConventionalWAG7 02-May-12BHEL14-Jun-12TransformerTFP oil leakageA34 bushing insulator top side oil leakage, same attended 43 5219 30304 CR AQ 3-PhaseWAP7 07-Dec-11CLW13-Jun-12Traction converter (SR)SLG 2 lifesign missing card type UAB514B33 no. 1005112 defectiveCard sent to firm for warranty replacement 19/06/12 189 5220 24581 NR LDH ConventionalWAG7 16-Feb-12BHEL13-Jun-12GR/RGR/CGRGR manual drive roll pin came out & fell down from coupling of shaft ( AAL make) Pin changed 118 5221 31328 ECR GMO 3-PhaseWAG9 03-Feb-12CLW13-Jun-12VCD/ TPWSCab-2 vigilance paddle switch not making contact. Same changed. 131 5222 31328 ECR GMO 3-PhaseWAG9 03-Feb-12CLW12-Jun-12Oil cooler blower unitBonded-All Phase earthed (C ). OCB-2 changed. 130 5223 24590 NR LDH ConventionalWAG7 27-Feb-12BHEL12-Jun-12SIVSmoke emission from SIV crow bar assembly Replaced by firm 106 5224 24572 NR LDH ConventionalWAG7 11-Nov-11BHEL11-Jun-12HT/LT cableQOP-1 & QOP-2 drop after 17th notch ET TFP-I found brust causing back side CTF-3 BAPT busbar no. H-36 , H-37 & G-12 Busbar no H-36 , H-37 & G-12 warnished & ET TFP-1 changed 213 5225 24572 NR LDH ConventionalWAG7 11-Nov-11BHEL11-Jun-12HT/LT cableQOP-1 & QOP-2 drop after 17th notch ET TFP-I found brust causing back side CTF-3 BAPT busbar no. H-36 , H-37 & G-12 Busbar no H-36 , H-37 & G-12 warnished & ET TFP-1 changed 213 5226 24612 NR LDH ConventionalWAG7 18-May-12BHEL11-Jun-12Axle Box1. Thrower of journal of axle no. 5 was free, deep cut & rubbing marks on thrower. 2. Thrower axle box.10 deep cut & rubbing marks resulting damage to thrower . 3.inner racer of axle box.10 make FAG WU2150X270 MI was fund cracked & sign of overheateding on it (12mm width thrower side) Axle with axle boxes has been replaced with new by ELS/LDH 24 5227 31315 ECR GMO 3-PhaseWAG9 10-May-12CLW11-Jun-12Traction converter (SR)ASC2 MUB GBC, SR2 229 Gate unit defective Gate unit changed 32 5228 31334 ECR GMO 3-PhaseWAG9 24-Feb-12CLW10-Jun-12Oil cooler blower unitImpeller blade broken. OCB-2 changed. 107 5229 22917 WR BRC ConventionalWAP4 20-Mar-12CLW10-Jun-12CBC/Draft gear/TSCWhile attaching on load at BDTS, cab2 side CBC coupler found defective. At BRC Shed found cab2 side CBC operating handle missing and rail guard bent as CRO occurred on 10.06.12 between UBR-GVD in BCT Division at km no. 136/19 while working train no. 14707. Same was informed by LP to TLC/BL. However, on arrival at BDTS, loco was not checked properly for CRO and damages caused due to CRO were not attended. Hence, trouble of CBC coupler was noticed while attaching loco on load. CBC operating handle provided and rail guard bent attended. 82 5230 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW09-Jun-12Oil cooler blower unitAll impeller blade broken. OCB-1 changed. 132 5231 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW09-Jun-12Transformer/ Converter oil pumpAbnormal sound-DE side bearing cage loose. 3306/SKF/Austria (N/M) SRP-1 changed. 132 5232 31327 ECR GMO 3-PhaseWAG9 29-Jan-12CLW08-Jun-12Traction converter (SR)Oil leakage from SR1 top oil pipe. Same tempurary attended with apply of M-seal. 131 5233 31334 ECR GMO 3-PhaseWAG9 24-Feb-12CLW08-Jun-12Aux. converter (BUR)BUR-1 off, Life sign missing. WRE changed. 105 5234 31334 ECR GMO 3-PhaseWAG9 24-Feb-12CLW08-Jun-12Bogie & its Mech. equip.Vertical damper-4 02 nos. both broken. Broken bolt removed bolt fitted. 105 5235 24580 NR LDH ConventionalWAG7 16-Feb-12BHEL08-Jun-12Bogie & its Mech. equip.Helical spring no. 2 inner coil broken Spring changed 113 5236 28459 SER BNDM ConventionalWAG7 22-May-12CLW07-Jun-12SIV"Battery charger was not working and fault message ‘CHBA voltage low & internal fault’ were displaying. It was found that the snubber card of input rectifier diode of battery charger was damaged. Details of SIV: Make: AAL, Sr. No.-OB1801112078, Type- GENERIC, DOC-27.05.12" M/s AAL's representative replaced snubber card 16 5237 31335 ECR GMO 3-PhaseWAG9 01-Mar-12CLW07-Jun-12Oil cooler blower unitAll impeller blade broken. OCB-1 changed. 98 5238 31322 ECR GMO 3-PhaseWAG9 01-Jan-12CLW05-Jun-12415V  MCBSometime (11-14) inter lock not close of SR-2 oil pump MCB Auxiliary-1 contactor. New Auxiliary-1 contactor of SR-2 oil pump MCB fitted. 156 5239 28453 SER BNDM ConventionalWAG7 13-Jun-12CLW05-Jun-12Traction Motor"During IC0, grease leakage from TM-3 pinion end bearing was detected. Details of TM: Sl. No.- 467-5295, Make-CLW, mfg. yr.- 02/12" TM was replaced -8 5240 28431 NCR CNB ConventionalWAG7 13-Mar-12CLW04-Jun-12Compressor/ExhausterCP-1 flexible tyre coupling damaged, Stud of both intake filter broken from base & crank shaft M-8 bolt bent, loose & threads worn out. Date of detection 04.06.12, CP-1 no. LM 0533, MCP no. KKAM2524, Make - Anest Iwata.CP-1 changed.83 5241 28431 NCR CNB ConventionalWAG7 13-Mar-12CLW04-Jun-12Compressor/ExhausterCP-1 flexible tyre coupling damaged, Stud of both intake filter broken from base & Crank shaft M-8 bolt bent, loose & threads worn out. DOC-10.03.12, Date of detection-04.06.12 CP-1 No.-LM 0533,MCP No. -KKAM2524, Make-: “Anest Iwata” Informed to CWM/CLW vide Tech-57, dt.05.06.12.83 5242 31323 ECR GMO 3-PhaseWAG9 07-Jan-12CLW04-Jun-12VCD/ TPWSCab-1 vigilance paddle switch stuck up. Same changed. 149 5243 24599 NR LDH ConventionalWAG7 10-May-12BHEL03-Jun-12SIVSIV internal fault Thermostat changed24 5244 22894 SER SRC ConventionalWAP4 25-Sep-11CLW02-Jun-12Vacuum Circuit Breaker (VCB)"Sometimes ICDJ. VCB trouble. Make - BT" "VCB changed. And warranty claimed to firm. Firm repaired." 251 5245 28457 SER TATA ConventionalWAG7 05-May-12CLW01-Jun-12Battery Charger (CHBA)CHBA not wkg. STC internal fault.Loco arrived to shed on 01.06.12 and found battery was dead condition. Loco BA charged through the mu loco by pressing PVEF in press condition. On 02.06.12 loco jointly checked with firm rep Mr. Anurag and found CHBA GDU card was defective as some time green LED (healthy) card was not glowing and same was replaced. Then Loco charged SIV Picking up normal but earth leakage level showing high in on-line monitoring in laptop and trips through external earth fault. From loco side checked and found –ve bonding which is related to 110V ckt and aux. Power circuit found normal, but SIV showing external ELD fault. found high frequency isolation transformer burnt( primary and secondary shorted) due to wrong connection on LC filter. Same was rectified and transformer changed.27 5246 22925 WCR ET ConventionalWAP4 12-Jun-12CLW31-May-12ESMONMaster SPM mother board was flashed & 50 pin connector was defective. Informed CEE (L & S) CLW on dtd. 26/06/12 vide L.No. ET/TRS/PPIO/30/124. -12 5247 31247 CR AQ 3-PhaseWAG9 25-May-10CLW31-May-12Central ElectronicsCP-2 contentious on URB 512 card defective CGL make card no 1006464Card sent to CGL for warranty replacement on 19/06/12737 5248 24597 NR LDH ConventionalWAG7 18-Mar-12BHEL30-May-12Axle BoxAxle nO -4 broken at the end of jurnal in ECR . Details of axle is as under Axle NO- AC-11-350 ( BHEL) Axle no 11-C -1614 of RWL, cast 02.0326 dated 24.09.11Axle changed73 5249 28436 SCR KZJ ConventionalWAG7 29-Apr-12CLW29-May-12TransformerHeavy sparks from the HT Compartment. Checked and found smoke coming from a-0 terminal.As per TS/ERS Checked and found a-1 & a-7 terminal connecting link spark due to loose contact.Same link plate was replaced with new one by shed.30 5250 28437 SCR KZJ ConventionalWAG7 16-Apr-12CLW28-May-12HT/LT cableTrain arrived WAT with HOBA in "OFF" position since CCPT repeatedly melting.loco moved to ELS/WAT,checked and found cable no 701 BD board earthed. Same attended and given ready.42 5251 24572 NR LDH ConventionalWAG7 11-Nov-11BHEL28-May-12Auxiliary MotorMVSL burnt MVSL changed ( M/s Ranjan)199 5252 31328 ECR GMO 3-PhaseWAG9 03-Feb-12CLW28-May-12Roof equipment/PantoPT-1 broken at TKD due to external hitting by OHE (as per logbook & PPO/TKD). Attended by ELS/TKD. 115 5253 31333 ECR GMO 3-PhaseWAG9 28-Feb-12CLW26-May-12MiscellaneousBPFA sometime sticking. BPFA new fitted. 88 5254 31333 ECR GMO 3-PhaseWAG9 28-Feb-12CLW26-May-12Compressor/Aux. compressorPressure not build up due to coupling free on checking found its coupling tyre damaged. Warranty failure claimed. 88 5255 24606 NR LDH ConventionalWAG7 23-Apr-12BHEL26-May-12GR/RGR/CGR SMGR control coil was defective Same coil changed by company staff 33 5256 24606 NR LDH ConventionalWAG7 23-Apr-12BHEL26-May-12SMGRSMGR trouble due to control coil defective Coil Changed 33 5257 28443 SCR KZJ ConventionalWAG7 12-May-12CLW25-May-12SIVLoco Pilot informed from ET Yard that Battery Charger not working.Firm staff attended & found SIV battery
1   ...   171   172   173   174   175   176   177   178   179

Related:

No of days after Commissioning iconKitiara, of all the days these days are locked in dark and waiting,...

No of days after Commissioning iconClinical commissioning group

No of days after Commissioning iconProfile Instrument Technician (Pre-Commissioning)

No of days after Commissioning iconFor supply, Installation, Testing and Commissioning of 33/11 kv external Electrification

No of days after Commissioning iconSupply installation testing & commissioning of air conditioners at peroorkada factory

No of days after Commissioning iconSub : Tender enquiry for Supply, Installation and Commissioning of...

No of days after Commissioning iconHave Varied Experience of in Project/ Routine Maintenance, Installation,...

No of days after Commissioning iconSenior level managerial assignments a Installation and Commissioning...

No of days after Commissioning iconNinety Days, Same As Cash

No of days after Commissioning iconSupply, Installation, Testing and Commissioning of 2 X 700 tr central...

No of days after Commissioning iconWeek Two Meal Planner 7 days for 2 adults

No of days after Commissioning iconWeek One Meal Planner 7 days for 2 adults

No of days after Commissioning iconWeek Three Meal Planner 7 days for 2 adults

No of days after Commissioning iconThe Days were a clan that mighta lived long

No of days after Commissioning iconOver 5,200 visitors: Arburg Technology Days 2011 sets new record

No of days after Commissioning iconWell here I am again. For some time now I am more calm and relaxed...

No of days after Commissioning icon“It takes eleven days to go from Horeb to Kadesh Barnea by the Mount Seir road.”

No of days after Commissioning iconUser Login Time (local): 12/31/2016 09: 49: 01 (4 days, 4 hours, 21 mins ago)

No of days after Commissioning iconExhibits and specialist presentations shed light on production efficiency at the Technology Days

No of days after Commissioning iconCroatia’s largest shopping centre is opening on 12 November with...




manual


When copying material provide a link © 2017
contacts
manual-guide.com
search