1hp proLiant snmp only Management Pack Guide


Download 90.73 Kb.
Name1hp proLiant snmp only Management Pack Guide
A typeDocumentation
manual-guide.com > manual > Documentation
HP ProLiant SNMP only Management Pack Guide for Operations Manager 2007

Raphael Burri

June, 2008

Revision History

Release Date

Changes

June, 2008

Original release of this guide











Contents

1 HP ProLiant SNMP only Management Pack Guide 4

2 Getting Started 5

2.1 Before importing the Management Pack 5

2.2 Other Requirements 6

2.2.1 SNMP Network Device Access 6

3 Elements of the HP ProLiant SNMP only management pack 7

3.1 Object Type Model 7

3.2 Object Discovery 8

3.2.1 Objects Discovered 8

3.3 Monitors 9

3.3.1 Advanced Memory Protection Status 10

3.3.2 ASR Status 10

3.3.3 Drive array status 10

3.3.4 Fibre Channel status 11

3.3.5 iLO Interface status 11

3.3.6 Management Log status 12

3.3.7 Network interface status 12

3.3.8 Power Supply status 12

3.3.9 Thermal Subsystem status 13

3.3.10 UPS status 13

4 Using the Management Pack 14

4.1 Console Views 14

1HP ProLiant SNMP only Management Pack Guide


The HP ProLiant SNMP only management pack monitors the health of Hewlett-Packard ProLiant server hardware, using SNMP get queries only.

It is thought as an add-on to HP’s management packs when no Operations Manager agents can be installed on the servers (non-windows operating system – namely VMware ESX servers).

The management pack requires at least Operations Manager 2007 SP1.

2Getting Started

2.1Before importing the Management Pack


The management pack consists of two files. Use the Import Management Pack function from the Administration pane of the Operations Console to import the management pack. Make sure you have all the management pack, the SNMP management pack depends on, imported as well. The import wizard will let you know if some are missing.

All dependencies are defined against management packs provided by Microsoft or HP. If you can’t find them on your Operations Manager installation media, you should be able to download them from here:

Microsoft: http://go.microsoft.com/fwlink/?LinkId=82105

HP: http://www.hp.com/servers/integration/microsoft (HP ProLiant Management Pack for System Center Operations Manager)

The following table lists the management pack files and the dependencies (in grey)

Management Pack File

Version

Vendor

Custom.HP.HewlettPackard.Servers.ProLiant.SNMPonly.mp

1.0.0.70

Custom

Custom.SNMP.Library.mp

1.0.0.1

Custom

HewlettPackard.Servers.Library.mp

1.0.33.0

HP

HewlettPackard.Servers.ProLiant.mp

1.0.33.0

HP

Microsoft.SystemCenter.InstanceGroup.Library.mp

6.0.6278.0

Microsoft

Microsoft.SystemCenter.Library.mp

6.0.6278.0

Microsoft

Microsoft.SystemCenter.NetworkDevice.Library.mp

6.0.6278.0

Microsoft

System.Health.Library.mp

6.0.6278.0

Microsoft

System.Library.mp

6.0.6278.0

Microsoft

System.Snmp.Library.mp

6.0.6278.0

Microsoft


2.2Other Requirements

2.2.1SNMP Network Device Access


This management pack gets all status and discovery information by SNMP gets against HP OIDs. The servers that should be monitored, have to have HP System Insight agent installed and their SNMP stack configured.

The Operations Manager management or gateway server designated as SNMP proxy node for the ProLiant system to be managed must be allowed get access to the relevant MIBs.

Discover the ProLiant systems (as Network Devices) using Operation Manager’s Discovery Wizard.

3Elements of the HP ProLiant SNMP only management pack

3.1Object Type Model


The following diagram shows the type model of the HP ProLiant SNMP only management pack. Inheritance is shown vertically while Hosting and Health Roll up are drawn horizontally. Blue object types are part of the management pack, while grey ones already exist. They are defined by the management pack’s dependencies.



Graphic 1

3.2Object Discovery

3.2.1Objects Discovered


The HP ProLiant SNMP only management pack discovers objects of the following types:

Object Type

Automatically

Discovery Rule

Attributes

HP Server SNMP only

Yes

Discover HP ProLiant Server (SNMP only)

  • Name

  • Network Name

  • Manufacturer

  • Model

  • Serial Number

  • System Firmware

  • HP Management Version

  • Monitoring Source

ASR (SNMP only)

Yes

Discover HP ProLiant ASR Object (SNMP only)




Drive Arrays (SNMP only)

Yes

Discover HP ProLiant Drive Array Object (SNMP only)




Advanced Memory Protection (SNMP only)

Yes

Discover HP ProLiant AMP Object (SNMP only)




Fibre Channel (SNMP only)

Yes

Discover HP ProLiant Fibre Channel Object (SNMP only)




iLO Interface (SNMP only)

Yes

Discover HP ProLiant iLO Interface Object (SNMP only)




Management Log (SNMP only)

Yes

Discover HP ProLiant Management Log Object (SNMP only)




Network Interface (SNMP only)

Yes

Discover HP ProLiant Network Interface Object (SNMP only)




Power Supplies (SNMP only)

Yes

Discover HP ProLiant Power Supplies Object (SNMP only)




Thermal Subsystem (SNMP only)

Yes

Discover HP ProLiant Thermal Subsystem Object (SNMP only)




UPS (SNMP only)

Yes

Discover HP ProLiant UPS Object (SNMP only)





3.3Monitors


The management pack defines ten monitors that keep track of the health of the objects discovered and generate alerts. These are targeted against different object types.

Simplified Health Explorer screen shot:





3.3.1Advanced Memory Protection Status


This monitor periodically checks the overall status of the ProLiant Advanced Memory Protection subsystem by querying the Compaq Health MIB (1.3.6.1.4.1.232.6)

OID checked for status degraded (3) or failed (4): cpqHeResilientMemCondition (1.3.6.1.4.1.232.6.2.14.4)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant Advanced Memory Protection failure

Only standard

none

Query cpqHeResilientMemCondition every 5 minutes


3.3.2ASR Status


This monitor periodically checks the overall status of the ProLiant Automatic Server Recovery (ASR) subsystem by querying the Compqaq Health MIB (1.3.6.1.4.1.232.6)

OID checked for status degraded (3) or failed (4): cpqHeAsrCondition (1.3.6.1.4.1.232.6.2.5.17)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant ASR status is degraded

Only standard

none

Query cpqHeAsrCondition every 5 minutes


3.3.3Drive array status


This monitor periodically checks the overall status of the ProLiant Drive Arrays by querying the Compaq Drive Array MIB (1.3.6.1.4.1.232.3)

OID checked for status degraded (3) or failed (4): cpqDaMibCondition (1.3.6.1.4.1.232.3.1.3)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant drive array status is degraded

Only standard

none

Query cpqDaMibCondition every 5 minutes


3.3.4Fibre Channel status


This monitor periodically checks the overall status of the ProLiant Fibre Channel subsystem by querying the Compqaq FC MIB (1.3.6.1.4.1.232.16)

OID checked for status degraded (3) or failed (4): cpqFcaMibCondition (1.3.6.1.4.1.232.16.1.3)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant Fibre Channel interface degraded

Only standard

none

Query cpqFcaMibCondition every 5 minutes

3.3.5iLO Interface status


This monitor periodically checks the overall status of the ProLiant iLO subsystem by querying the Compaq iLO MIB (1.3.6.1.4.1.232.9)

OID checked for status degraded (3) or failed (4): cpqSm2MibCondition (1.3.6.1.4.1.232.9.1.3)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant iLO interface failure

Only standard

none

Query cpqSm2MibCondition every 5 minutes

3.3.6Management Log status


This monitor periodically checks the overall status of the ProLiant integrated Management Log (IML) by querying the Compaq Health MIB (1.3.6.1.4.1.232.6)

OID checked for status degraded (3) or failed (4): cpqHeEventLogCondition (1.3.6.1.4.1.232.6.2.11.2)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant Integrated Management Log entry pending

Only standard

none

Query cpqHeEventLogCondition every 5 minutes

3.3.7Network interface status


This monitor periodically checks the overall status of the ProLiant Network Interface subsystem by querying the Compaq NIC MIB (1.3.6.1.4.1.232.18)

OID checked for status degraded (3) or failed (4): cpqNicMibCondition (1.3.6.1.4.1.232.18.1.3)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant network interface degraded

Only standard

none

Query cpqNicMibCondition every 5 minutes

3.3.8Power Supply status


This monitor periodically checks the overall status of the ProLiant Fault Tolerant Power Supplies subsystem by querying the Compaq Health MIB (1.3.6.1.4.1.232.6)

OID checked for status degraded (3) or failed (4): cpqHeFltToPwrSupplyCondition (1.3.6.1.4.1.232.6.2.9.1)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant redundant power supply status is degraded

Only standard

none

Query cpqHeFltToPwrSupplyCondition every 5 minutes

3.3.9Thermal Subsystem status


This monitor periodically checks the overall status of the ProLiant Thermal Health subsystem by querying the Compaq Health MIB (1.3.6.1.4.1.232.6)

OID checked for status degraded (3) or failed (4): cpqHeThermalCondition (1.3.6.1.4.1.232.6.2.6.1)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant thermal subsystem status is degraded

Only standard

none

Query cpqHeThermalCondition every 5 minutes

3.3.10UPS status


This monitor periodically checks the overall status of the ProLiant UPS subsystem by querying the Compaq UPS MIB (1.3.6.1.4.1.232.12)

OID checked for status degraded (3) or failed (4): cpqUpsMibCondition (1.3.6.1.4.1.232.12.1.3)

Severity

Alert Name

Possible Overrides

Diagnostic and Recovery Tasks

Implementation Details

Warning

HP ProLiant UPS degraded

Only standard

none

Query cpqUpsMibCondition every 5 minutes

4Using the Management Pack


After importing the management pack, discovery and monitoring is going to work automatically. All SNMP network devices found in Operations Managers repository are going to be queried to check if they represent HP ProLiant servers.

4.1Console Views


This management pack does not define additional views. It makes use of the ones defined by HP’s management packs. In Operations Manager’s Console, the monitoring pane contains the following views under ‘HP Servers’.

  • Active Alerts

  • Computers

  • Group State

  • Health Collection State

  • HP Management Servers

  • Server Diagram

  • Server State

  • Task Status

T
he ones in bold type do include information about SNMP only managed ProLiant servers.

Share in:

Related:

1hp proLiant snmp only Management Pack Guide iconGuide for System Center Management Pack for Active Directory for Operations Manager 2012

1hp proLiant snmp only Management Pack Guide iconGuide for System Center Management Pack for Active Directory for Operations Manager 2012

1hp proLiant snmp only Management Pack Guide iconOnline Documentation for ProLiant Servers Best Practices for vmware...

1hp proLiant snmp only Management Pack Guide iconOnline Documentation for ProLiant Servers Best Practices for vmware...

1hp proLiant snmp only Management Pack Guide iconMicrosoft System Center Configuration Manager 2007 Management Pack...

1hp proLiant snmp only Management Pack Guide iconApplication Note Connecting to a 1609 ups using snmp, Hirchmann hiopc and an opc client

1hp proLiant snmp only Management Pack Guide iconRisk Management Guide

1hp proLiant snmp only Management Pack Guide icon½ atr chassis Management User Guide

1hp proLiant snmp only Management Pack Guide iconS hipShape Weight Management Program Facilitator’s Guide

1hp proLiant snmp only Management Pack Guide iconSecurity Management Suite Guide Specifications in csi format

1hp proLiant snmp only Management Pack Guide icon1 Install the battery pack 2

1hp proLiant snmp only Management Pack Guide iconLiebert® pdx™ and pcw™ Nominal 11, 17, 18, 23 or 29 kw thermal Management...

1hp proLiant snmp only Management Pack Guide iconB. Competition Life Cycle Project Management Guide, Strategic Sourcing Program

1hp proLiant snmp only Management Pack Guide iconB ureau of indian affairs agency administrator’s guide to Critical Incident Management

1hp proLiant snmp only Management Pack Guide iconFujitsu ServerView pro pack for

1hp proLiant snmp only Management Pack Guide iconJjc li-ion Battery Pack

1hp proLiant snmp only Management Pack Guide iconH rd strategy Resource Pack: Part 2

1hp proLiant snmp only Management Pack Guide iconCurriculum for Excellence Level 3 Assessment Pack

1hp proLiant snmp only Management Pack Guide iconNvr device Pack Release Note

1hp proLiant snmp only Management Pack Guide iconUser Management, Resource Management and Application Management




manual


When copying material provide a link © 2017
contacts
manual-guide.com
search