User Capacity




Download 72.01 Kb.
NameUser Capacity
A typeUser
manual-guide.com > manual > User
Updated: 05/14/2009

Eternity-III (V4.0) Manual Operation Guide

General Information:


  • User Capacity: 300

  • Index: 001 ~ 300

  • Access mode: iButton, code, ibutton+code, manual key override

  • Program code: up to 8 digits

  • User code / service code: up to 8 digits

  • Exit Setting: Enter * to exit the setting procedure if error occurred, or wait for about 10 seconds

  • Low battery warning: When Voltage drops below 4.8V, after enter a valid code, the red LED will flash and beep five times.

  • Reset Button: To set the lock back to default setting 123456 & clear all memory, press and hold the reset button about 10 seconds (3 beeps with LED blink red). The reset button is located below the battery holder.




Manufacture Default Setting:

  • Daylight Saving: Disabled

  • Auto unlock/lock: Disabled

  • Default Program Code: 123456

  • Lock Mode: Storehouse



Types to operate the lock:


  • Keycode: User Code #

  • iButton: iButton key touch lock reader

  • iButton+Keypad: iButton touch lock reader, LED grow green, enter user code #

  • One time service code: One time code #

  • Manual key: Turn the override key 90 degree clockwise, then turn the handle



Terms:


Program code: The Program code, also called programming code, puts the lock into a programming mode. It will not lock/unlock the lock. When #, Program code, # is entered, the red LED start to flash indicating the lock is in a programming mode. If more than 6 seconds exceed in between programming entries, the lock return to normal operational status. It is necessary to change the default Program code
Installer code: Installer code is a default temporary code (0) for installer testing the lock. The code will be deleted after new user codes added to the lock.
User code: User code is the Normal code for the day-to-day operations.
Service code: Service Codes are used for a special purpose such as maintenance personnel or vendors. Service Code only grants one time access. Up to 10 sets of service codes can be programmed to each lock
Index #: Each code or iButton will associate with a unique number, we call it index# (or slot#). The Index # is auto generated by lock and start with 001. The highest Index# will be 299; therefore up to 300 users can be added to each lock.

(* Please log the user code along with its index # for future reference)
Passage mode: When Passage Mode is enabled, the lock will stay in unlock after first valid entry. Re-enter a valid entry to lock back.

Storehouse mode: for each valid entry, lock will automatically lock back in 5 seconds.
Lockout: Enable the Lockout mode will freeze the lock at its current state (Lock or unlock), temporarily disable all the user codes and iButton keys. Re-enter the function code 99 again to disable the lockout mode
Clearing lock memory: Press and hold reset button for 10 seconds with 3 short beeps, it will delete all the codes and iButtons and restore the Program code to factory default setting (123456)
How to change programming code (and not delete existing user codes)

  • Function Code: 11#

    • {#}+{default Program code#}+{11#}+{new Program code#}+{new Program code#}


How to change programming code (and delete all existing user codes)

  • Function code: 22#

    • {#}+{current Program code#}+{22#}+{new Program code#}+{new Program code#}


How to enable daytime saving

  • Function Code: 31#

    • {#Program code#}+{31#}



How to set date and time

  • Function Code: 88#

    • {#Program code#}+{88#}+{yymmddhhmm#}


How to add one user code (no time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+{user code# # #}


How to add multi-user code (no time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+{user code(1)# # #}+{user code(2)# # #}+{user code3###} … and so on


How to add one user access code (with time restriction)

  • Function Code: 01#

{#Program code#}+{01#}+{user code#}+{yymmddhhmm#(start time)}+{yymmddhhmm#(ending time)}


How to add multi-user code (with time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+{user code#(1)}+{yymmddhhmm#(start)}+{yymmddhhmm#(ending time)} + {user code#(2)}+{yymmddhhmm#(start)}+{yymmddhhmm#(ending)} …and so on

How to add one iButton key (no time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+{touch iButton # #}


How to add multi-user iButton key (no time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+{iButton(1)# #}+{ibutton(2)# #} …and so on


How to add user code + iButton key as dual security (no time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+{user code#}+{touch iButton# #}


How to add one iButton key (with time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+tab { iButton}+{yymmddhhmm#(start time)}+{yymmddhhmm#(ending time)}


How to add multi-iButton key (with time restriction)

  • Function Code: 01#

    • {#Program code#}+{01#}+tab {iButton key(1)}+{yymmddhhmm#(start)}+{yymmddhhmm#(end time)}+ tab {iButton key(2)}+{yymmddhhmm#(start)}+{yymmddhhmm#(end time)} …and so on


How to disable one user code or iButton key with index#

  • Function Code: 02#

    • {#Program code#}+{02#}+{index #}


How to enable one user code or iButton key with index#

  • Function Code: 03#

    • {#Program code#}+{03#}+{index code#}


How to enable / disable passage mode (on & off)

  • Function Code: 15#

    • {#Master#}+{15#}


How to disable passage mode

  • Function Code: 16#

    • {#Master#}+{16#}


How to enable LED blink light (on & off)

  • Function Code: 18#

    • {#Program code#}+{18#}


How to disable daytime saving

  • Function Code: 32#

    • {#Program code#}+{32#}


How to set up one time service code (up to 10 service codes)

  • Function Code: 33#

  • {#Program code#}+{33#}+{service code(1)# }+ {service code(2)# }+… and so on


How to delete user code or iButton key (with index #)

  • Function Code: 44#

    • {#Program code#}+{44#}+{index#}


How to enable auto-unlock function

  • Function Code: 64#

  • {#Program code#}+{64#}


How to setup auto-unlock time (it will auto unlock the door everyday at assigned time)

  • Function Code: 63#

    • {#Program code#}+{63#}+{HHMM#}

How to disable auto-unlock function

  • Function Code: 65#

    • {#Program code#}+{65#}


How to enable auto-lock function

  • Function Code: 67#

  • {#Program code#}+{67#}


How to setup auto-lock time (it will auto lock the door everyday at assigned time)

  • Function Code: 66#

  • {#Program code#}+{66#}+{HHMM#}


How to disable auto-lock function

  • Function Code: 68#

    • {#Program code#}+{68#}


How to enable / disable Lock-out (lock out all users if enabled)

  • Function Code: 99#

    • {#Program#}+{99#}




  • How to program schedule week & time with Function Code: (45#)

  • 1st enable daylight saving

  • 2nd set up date & time (use 88# function code)

  • 3rd adding user code / iButton key or dual security code in advance (see above how to add user code & iButton)

  • 4th program schedule (as below)



Weekly Chart


Sun

Mon

Tue

Wed

Thu

Fri

Sat

7

1

2

3

4

5

6

Formula: {#Program code#}+{function code#}+{user code# or iButton}+{select week number#}+{begin time & ending time#}

  • How to program schedule with an “user code”

Example: {#23456# + 45# + 2222# + 135# + 08301730#} ; Timing: 0830= 8:30am ; 1730=5:30pm

#23456#

45#

2222#

135#

0830

1730#

Program code

Function code

User code

Mon/Wed/Fri

Beginning time

Ending time


Warning: failure to pre-set {user code} before start program schedule will block to continuing…

  • How to program schedule with “iButton Key”

Example: {#23456# + 45# + iButton + 135# + 08301730#}

#23456#

45#

IButton key

135#

0830

1730#

Program code

Function code

iButton

Mon/Wed/Fri

Beginning time

Ending time


Warning: failure to pre-set {iButton key} before start program schedule will block to continuing…

  • How to program schedule with “Key-code + iButton”

Example: {#23456# + 45# + user-code# + iButton + 135# + 08301730#}

#23456#

45#

User-code# + iButton

135#

0830

1730#

Program code

Function code

user code + iButton

Mon/Wed/Fri

Beginning time

Ending time


Warning: failure to pre-set {dual security code} before start program schedule will block to continuing…

Index #


User Name

User Code


001







002







003







004







005







006







007







008







009







010







011







012







013







014







015







016







017







018







019







020







021







022







023







024







025







026







027







028







029







030







031







032







033







034







035







036







037







038







039







040










*** Up to 300 users ***










Share in:

Related:

User Capacity iconUser manual Capacity of basement fuel tank (L) :220

User Capacity iconUsers Capacity

User Capacity iconLooking For Overstocks / Over Capacity-Any Product Welcome! !

User Capacity iconUnsaturated iron binding capacity

User Capacity iconCapacity Range: 6 to 0 Ton Nominal

User Capacity iconOpm v5 capacity planning estimate

User Capacity iconJennifer granholm in her official capacity

User Capacity iconMemory Capacity, Motorola-Architecture Machines 14

User Capacity iconWhat does the high storage capacity of the Blu-ray Disc offer to users?

User Capacity iconSeries High Capacity nxt3000 System Specification Equipment Description

User Capacity iconJoint Programme on Strengthening Institutional Capacity for Development...

User Capacity iconDecisions on system capacity, location of facilities, arrangement...

User Capacity iconEquipped with 4 A2-6 Spindles, 4500rpm, 20 max hp, Fanuc 18iT 4-axis...

User Capacity iconShanghai gm dong Yue Motors Vehicle Manufacturing Facility Completes...

User Capacity iconDespite the success of the compact disc there has been a clear need...

User Capacity iconAbstract This book provides information about planning for capacity...

User Capacity iconThe Jagunda bird feeder provides complete squirrel protection when...

User Capacity iconIt is the intent of the Government to purchase 300 gallon capacity...

User Capacity iconAssessing Provincial and District Health System Capacity to Sustain...

User Capacity iconPD40 flashlight boasts the best output to weight ratios among Fenix...




manual




When copying material provide a link © 2017
contacts
manual-guide.com
search